Metraipolis › archive › dc_ff18869c3cc3

Passive Identification of Unequal Phase Grid Impedances by Phase-Domain Source Cancellation — arXiv:2610.38131

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.38131
License (as archived)
CC0-1.0
Archived
2026-11-01T02:59:28.116Z
SHA-256 of the archived text
52ac061988e5fef186e85338fdc98cd57eccaf33e60a9021b113b5a9492d0fe1
Stable URL of this page
https://metraipolis.com/documento/dc_ff18869c3cc3

How to cite

Passive Identification of Unequal Phase Grid Impedances by Phase-Domain Source Cancellation — arXiv:2610.38131 — arXiv (en), https://arxiv.org/abs/2610.38131 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ff18869c3cc3 (Metraipolis archive dc_ff18869c3cc3, sha256 52ac061988e5fef186e85338fdc98cd57eccaf33e60a9021b113b5a9492d0fe1)
BibTeX
@misc{dcff18869c3cc3,
  title = {Passive Identification of Unequal Phase Grid Impedances by Phase-Domain Source Cancellation — arXiv:2610.38131},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.38131},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ff18869c3cc3; sha256 52ac061988e5fef186e85338fdc98cd57eccaf33e60a9021b113b5a9492d0fe1},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.38131. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Passive grid impedance estimators that return a single resistance--inductance pair cannot represent a grid whose phase impedances are unequal. This paper identifies a separate pair for each phase from recorded point-of-common-coupling (PCC) voltage and current without injected perturbations. In each phase, the unknown grid-source voltage is cancelled by a periodic difference (PD) or by a second-order-generalized-integrator notch difference (SOGID), and moving-window integration (MWI) replaces the current derivative by an integral and an endpoint feature. The resulting two-parameter regression requires a period or notch-frequency estimate but no phase-locked-loop angle. A voltage-balance analysis gives the source residual left by frequency mismatch and bounds the parameter error by the ratio of this residual to the conditioning of the two features. In the unequal-phase interval (8.3--9.8~s) of a 10-s EMTP grid-forming record, SOGID-MWI attains phase-averaged R/L errors of 5.09/0.33\%; a shared value has a minimum error of 41.67\% for the phase ratio 1:0.5:2. On a 50-s constant-impedance grid-following record, the errors are 0.56/0.06\% over the 20--30-s synchronization disturbance. In a controlled 40-dB noise study, a noise-referenced update rule reduces the white-noise GFL error from 55.9/65.0\% to 12.3/11.5\%.

Tema degli esploratori: calcolo e infrastrutture (elenco arXiv eess.SY, nuovi lavori del giorno).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2610.38131 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-01T02:25:30.723Z dalla pagina https://arxiv.org/list/eess.SY/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).