Metraipolis › archive › dc_fecf5b85ad9a

PathoJev: Efficient Pathology Decisions from Shared Visual Context — arXiv:2610.40752

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.40752
License (as archived)
CC0-1.0
Archived
2026-11-02T08:02:38.966Z
SHA-256 of the archived text
deb9aea9277134bf30f88339e06ee1cf2091a091e31e78c1c6c0fc215c7e3f90
Stable URL of this page
https://metraipolis.com/documento/dc_fecf5b85ad9a

How to cite

PathoJev: Efficient Pathology Decisions from Shared Visual Context — arXiv:2610.40752 — arXiv (en), https://arxiv.org/abs/2610.40752 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_fecf5b85ad9a (Metraipolis archive dc_fecf5b85ad9a, sha256 deb9aea9277134bf30f88339e06ee1cf2091a091e31e78c1c6c0fc215c7e3f90)
BibTeX
@misc{dcfecf5b85ad9a,
  title = {PathoJev: Efficient Pathology Decisions from Shared Visual Context — arXiv:2610.40752},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.40752},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_fecf5b85ad9a; sha256 deb9aea9277134bf30f88339e06ee1cf2091a091e31e78c1c6c0fc215c7e3f90},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.40752. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Pathology workflows require multiple visual judgments about the same slide, from identifying tumor type to assessing grade and invasion. Generating and parsing a separate textual response for each structured question adds latency between visual evidence and usable decisions. Building on the System One paradigm, we introduce PathoJev, a pathology model that directly predicts answer probabilities for whole-slide and region-level assessment. PathoJev encodes each slide once and evaluates independent question suffixes in batches over the shared visual context. Reusing the hybrid backbone's recurrent states further limits the computation that grows with slide-context length for each additional question. Across three whole-slide benchmarks, the 9B and 27B models achieve mean accuracies of 77.2% and 78.1%, exceeding SlideChat by 5.4 and 6.3 percentage points. Both scales also maintain competitive accuracy on five ROI benchmarks. On WSI-Bench, the 9B model runs 9.1x faster than SlideChat. Shared context accelerates eight-question workloads by 6.9x and 5.9x over separate prefix encoding, rising to 11.2x and 8.9x for 64 questions. These results provide a reusable probabilistic interface for combining multiple visual judgments in whole-slide and local tissue assessment. Code: this https URL .

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2610.40752 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-02T07:44:00.721Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).