Metraipolis › archive › dc_fdd80b07690d
Directional Dual-Head Supervision for Real-Time Source-Free Polyp Segmentation — arXiv:2611.00238
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.00238
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-03T18:56:48.490Z
- SHA-256 of the archived text
4ed0528fcc9561b285dbf46e827b6f75387cbaf386743e44ddbea649d1d054a4- Stable URL of this page
https://metraipolis.com/documento/dc_fdd80b07690d
How to cite
Directional Dual-Head Supervision for Real-Time Source-Free Polyp Segmentation — arXiv:2611.00238 — arXiv (en), https://arxiv.org/abs/2611.00238 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_fdd80b07690d (Metraipolis archive dc_fdd80b07690d, sha256 4ed0528fcc9561b285dbf46e827b6f75387cbaf386743e44ddbea649d1d054a4)
BibTeX
@misc{dcfdd80b07690d,
title = {Directional Dual-Head Supervision for Real-Time Source-Free Polyp Segmentation — arXiv:2611.00238},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.00238},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_fdd80b07690d; sha256 4ed0528fcc9561b285dbf46e827b6f75387cbaf386743e44ddbea649d1d054a4},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.00238. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Source-free domain adaptation (SFDA) is critical for medical image segmentation as it adapts a model to an unlabeled target domain without accessing source data, thereby preserving data privacy. However, its effectiveness is often limited by confirmation bias: self-training models tend to miss small polyps, hallucinate foreground, and produce imprecise contours. We propose MedRT-SFSeg, a real-time SFDA framework built on a dual-head one-to-one/one-to-many YOLO segmentation architecture. Mask-DHF fuses precision- and recall-oriented predictions into stable pseudo-instances, while DURR uses the sign of pixel-level dual-head disagreement as a directional cue to expand or shrink masks, and additionally recovers missed instances and suppresses hallucinations. Seg-MARD further regularizes feature representations through mask-guided, region-stratified sampling. Experiments on bidirectional adaptation between Kvasir-SEG and CVC-ClinicDB show that MedRT-SFSeg achieves 80.43%/80.77% Dice and 5.53/8.44 mm ASD, improving the non-adapted baseline by 7.7 and 9.8 Dice points while running at more than 62 FPS end-to-end. These results suggest that segmentation-aware dual-head supervision can improve pseudo-label quality without sacrificing real-time inference. Project page: this https URL Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno). Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2611.00238 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-03T18:16:53.102Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).