Metraipolis › archive › dc_f8d7d903841a

Comparing the contrast performance of two IFU technologies for exoplanet direct imaging with ELT-PCS — arXiv:2608.05361

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.05361
License (as archived)
CC0-1.0
Archived
2026-10-31T11:03:20.974Z
SHA-256 of the archived text
b0ad5084215ebca30b8ebfaa7b1ed26a67134bdaa1db2396f47986d27d623385
Stable URL of this page
https://metraipolis.com/documento/dc_f8d7d903841a

How to cite

Comparing the contrast performance of two IFU technologies for exoplanet direct imaging with ELT-PCS — arXiv:2608.05361 — arXiv (en), https://arxiv.org/abs/2608.05361 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f8d7d903841a (Metraipolis archive dc_f8d7d903841a, sha256 b0ad5084215ebca30b8ebfaa7b1ed26a67134bdaa1db2396f47986d27d623385)
BibTeX
@misc{dcf8d7d903841a,
  title = {Comparing the contrast performance of two IFU technologies for exoplanet direct imaging with ELT-PCS — arXiv:2608.05361},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.05361},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f8d7d903841a; sha256 b0ad5084215ebca30b8ebfaa7b1ed26a67134bdaa1db2396f47986d27d623385},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.05361. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

A key science goal for the Planetary Camera and Spectrograph (ELT-PCS) instrument is to image rocky exoplanets in reflected light around nearby M- and K-dwarfs. These observations will require a contrast of 10^(-9) at 100 mas angular separation, and 10^(-8) at 10 mas. To achieve such an extreme performance, every instrument design choice must be carefully evaluated. For ELT-PCS's science instruments, perhaps the most critical design choice is which integral field unit (IFU) technology to use. To this end, we have developed a modular, lab-based integral field spectrograph test bench with which to compare the performance of two popular IFU technologies: image slicers and lenslet arrays. The test bench implements a Lyot coronagraph and a spatial light modulator to simulate a high-contrast imaging system, which feeds each IFU with a diffraction-limited PSF image. Each IFU is coupled to the spectrograph, which achieves R ~ 3000 with the image slicer and R ~ 100 with the lenslet array. The calibration and data reduction for each IFU design are described and the initial results of a contrast comparison are presented. The lenslet array achieves a deeper contrast at angular separations of less than 6 lambda/D. The image slicer, however, gains more at small separations from applying spectral deconvolution, with a 3.4x greater gain at 4 lambda/D. Spectral deconvolution further yields a contrast curve close to the detector noise floor. Further work will focus on carrying out a fully-controlled characterisation of the lenslet array IFU and a more comprehensive study into the effects of adaptive optics residuals on the contrast.

Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-08-07 in astro-ph.IM).
Categorie arXiv: Instrumentation and Methods for Astrophysics (astro-ph.IM).
Pagina del lavoro: https://arxiv.org/abs/2608.05361 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-31T10:53:55.699Z dalla pagina https://arxiv.org/catchup/astro-ph.IM/2026-08-07?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).