Metraipolis › archive › dc_f8d1afa31ff4

Visible Human Project® female surface based computational phantom (Nelly) for radio-frequency safety evaluation in MRI coils — Europe PMC PMID:34890429

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/34890429
DOI
10.1371/journal.pone.0260922
License (as archived)
CC0-1.0
Archived
2026-11-01T03:19:44.248Z
SHA-256 of the archived text
5ae555220fb85fa4b7f84d1030e45f98ef1da0da117130d4c52ab01587e54f7e
Stable URL of this page
https://metraipolis.com/documento/dc_f8d1afa31ff4

How to cite

Visible Human Project® female surface based computational phantom (Nelly) for radio-frequency safety evaluation in MRI coils — Europe PMC PMID:34890429 — Europe PMC (en), https://europepmc.org/article/MED/34890429 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f8d1afa31ff4 (Metraipolis archive dc_f8d1afa31ff4, sha256 5ae555220fb85fa4b7f84d1030e45f98ef1da0da117130d4c52ab01587e54f7e)
BibTeX
@misc{dcf8d1afa31ff4,
  title = {Visible Human Project® female surface based computational phantom (Nelly) for radio-frequency safety evaluation in MRI coils — Europe PMC PMID:34890429},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/34890429},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f8d1afa31ff4; sha256 5ae555220fb85fa4b7f84d1030e45f98ef1da0da117130d4c52ab01587e54f7e},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/34890429. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Quantitative modeling of specific absorption rate and temperature rise within the human body during 1.5 T and 3 T MRI scans is of clinical significance to ensure patient safety. This work presents justification, via validation and comparison, of the potential use of the Visible Human Project (VHP) derived Computer Aided Design (CAD) female full body computational human model for non-clinical assessment of female patients of age 50-65 years with a BMI of 30-36 during 1.5 T and 3 T based MRI procedures. The initial segmentation validation and four different application examples have been identified and used to compare to numerical simulation results obtained using VHP Female computational human model under the same or similar conditions. The first application example provides a simulation-to-simulation validation while the latter three application examples compare with measured experimental data. Given the same or similar coil settings, the computational human model generates meaningful results for SAR, B1 field, and temperature rise when used in conjunction with the 1.5 T birdcage MRI coils or at higher frequencies corresponding to 3 T MRI. Notably, the deviation in temperature rise from experiment did not exceed 2.75° C for three different heating scenarios considered in the study with relative deviations of 10%, 25%, and 20%. This study provides a reasonably systematic validation and comparison of the VHP-Female CAD v.3.0-5.0 surface-based computational human model starting with the segmentation validation and following four different application examples.

Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera).
Pubblicazione: PloS one, 2021 (prima pubblicazione 2021-12-10).
Identificativi: PMID 34890429 · PMCID PMC8664205 · DOI 10.1371/journal.pone.0260922.
Descrittori MeSH principali: Visible Human Projects.
Pagina: https://europepmc.org/article/MED/34890429 — https://doi.org/10.1371/journal.pone.0260922. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0.
Letto il 2026-11-01T03:11:04.737Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.