Metraipolis › archive › dc_f8600cc85a1b
Tactile Sensing Array for Multi-Phalanx Sensing in Humanoid Hands — arXiv:2609.30506
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.30506
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T03:14:42.859Z
- SHA-256 of the archived text
0c9b0e26ffe7dcb5fe6dec8ea727e498291fe96392e9df6d0d790682935db998- Stable URL of this page
https://metraipolis.com/documento/dc_f8600cc85a1b
How to cite
Tactile Sensing Array for Multi-Phalanx Sensing in Humanoid Hands — arXiv:2609.30506 — arXiv (en), https://arxiv.org/abs/2609.30506 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f8600cc85a1b (Metraipolis archive dc_f8600cc85a1b, sha256 0c9b0e26ffe7dcb5fe6dec8ea727e498291fe96392e9df6d0d790682935db998)
BibTeX
@misc{dcf8600cc85a1b,
title = {Tactile Sensing Array for Multi-Phalanx Sensing in Humanoid Hands — arXiv:2609.30506},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.30506},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f8600cc85a1b; sha256 0c9b0e26ffe7dcb5fe6dec8ea727e498291fe96392e9df6d0d790682935db998},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.30506. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Humanoid hands require tactile feedback across the whole finger, not just the fingertip, to grasp and manipulate objects properly. Vision and proprioception alone cannot reliably provide this information, particularly when the hand's own fingers occlude the camera's view of the grasp. We present a low-cost tactile array for a humanoid finger, made from Velostat and conductive tape. The fingertip carries seven contact points including a 2x3 matrix wrapped across its front, left, and right faces, and a separate contact point at the tip. The proximal and middle phalanges each carry a single front-facing contact line. We measure the sensor's hysteresis and recovery time after release, through repeated loading and press-release tests. We also test a compliant, 3D-printed contact structure with a gap and a bump, inspired by similar designs in prior work, and show it cuts recovery time by 74% compared to a flush-contact baseline. We then show the sensor can produce distinct activation patterns for different contact geometries (flat, edge, corner) at the fingertip, and that it registers contact across all three phalanges during a grip. Finally, we discuss the limits of our fabrication changes and point to software-based compensation as a promising way to more directly fix the remaining hysteresis in the future. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-28 in cs.RO). Categorie arXiv: Robotics (cs.RO) ; Emerging Technologies (cs.ET). Pagina del lavoro: https://arxiv.org/abs/2609.30506 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T02:58:08.793Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-09-28?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).