Metraipolis › archive › dc_f7fdfbe31229
Physically Constrained Kinematic Calibration for High-Precision Robotic Needle Guidance — arXiv:2610.41429
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.41429
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-02T04:57:32.986Z
- SHA-256 of the archived text
1f8c8a7cecacb234e519779b361f5b30999917b6638c649bbed32f1a4bfc22ca- Stable URL of this page
https://metraipolis.com/documento/dc_f7fdfbe31229
How to cite
Physically Constrained Kinematic Calibration for High-Precision Robotic Needle Guidance — arXiv:2610.41429 — arXiv (en), https://arxiv.org/abs/2610.41429 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f7fdfbe31229 (Metraipolis archive dc_f7fdfbe31229, sha256 1f8c8a7cecacb234e519779b361f5b30999917b6638c649bbed32f1a4bfc22ca)
BibTeX
@misc{dcf7fdfbe31229,
title = {Physically Constrained Kinematic Calibration for High-Precision Robotic Needle Guidance — arXiv:2610.41429},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.41429},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f7fdfbe31229; sha256 1f8c8a7cecacb234e519779b361f5b30999917b6638c649bbed32f1a4bfc22ca},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.41429. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Percutaneous needle insertion is a common practice in minimally invasive procedures whose clinical success depends on accurate needle placement. However, achieving the necessary precision is a challenge for manual operators. Robotic assistance can improve targeting accuracy and reduce operator dependence, but residual millimeter-scale errors persist because nominal kinematic models do not fully represent the physical manipulator. This paper presents a robust bound-constrained kinematic calibration method designed to improve positional accuracy for a 6-Degree-of-Freedom (6-DoF) robotic needle-guidance manipulator. The approach uses physically plausible parameter ranges to regularize a compact 19-parameter geometric identification model. By treating these bounds as active optimization constraints rather than mere numerical safeguards, the framework effectively mitigates parameter coupling and overfitting, ensuring highly stable parameter identification. In simulation, the proposed method reduced end-effector Root Mean Square Error (RMSE) from 3.422 mm to 0.690 mm (a 79.8% improvement). In benchtop hardware experiments, the calibrated model achieved sub-millimeter validation accuracy, including 0.865 mm RMSE in experimental trajectory validation and 0.610 mm RMSE in a coordinate-lattice verification task. These results demonstrate that physically constrained kinematic calibration can enhance robotic needle-targeting accuracy, establishing a high-precision foundation for future clinical applications. Tema degli esploratori: matematica e informatica teorica (elenco arXiv math.OC, nuovi lavori del giorno). Categorie arXiv: Robotics (cs.RO) ; Systems and Control (eess.SY); Optimization and Control (math.OC). Pagina del lavoro: https://arxiv.org/abs/2610.41429 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-02T04:46:57.687Z dalla pagina https://arxiv.org/list/math.OC/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).