Metraipolis › archive › dc_f7da34058375

Calibration of Toenail Metal Concentrations for Sample Mass Heterogeneity and Between-Batch Variability: The COMET Approach — Europe PMC PMID:40052947

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/40052947
DOI
10.1289/ehp14784
License (as archived)
CC0-1.0
Archived
2026-10-06T11:30:54.331Z
SHA-256 of the archived text
81f5ae1ece3f7073ed1b56549b80948f083ba10c8e591e34cc1a3aaa69a7e29c
Stable URL of this page
https://metraipolis.com/documento/dc_f7da34058375

How to cite

Calibration of Toenail Metal Concentrations for Sample Mass Heterogeneity and Between-Batch Variability: The COMET Approach — Europe PMC PMID:40052947 — Europe PMC (en), https://europepmc.org/article/MED/40052947 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f7da34058375 (Metraipolis archive dc_f7da34058375, sha256 81f5ae1ece3f7073ed1b56549b80948f083ba10c8e591e34cc1a3aaa69a7e29c)
BibTeX
@misc{dcf7da34058375,
  title = {Calibration of Toenail Metal Concentrations for Sample Mass Heterogeneity and Between-Batch Variability: The COMET Approach — Europe PMC PMID:40052947},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/40052947},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f7da34058375; sha256 81f5ae1ece3f7073ed1b56549b80948f083ba10c8e591e34cc1a3aaa69a7e29c},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/40052947. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Background: Toenails are promising biomarkers of long-term metal exposure in epidemiological studies, but their accuracy may be compromised by systematic and random errors associated with heterogeneous toenail sample masses, as well as by substantial variability across laboratory batches. Objectives: We propose a novel modeling approach to calibrate toenail metal concentrations for the heterogeneity in sample masses and the variability between batches. Methods: We developed a heteroscedastic spline mixed model relating sample mass and laboratory batch with measured concentrations, allowing for an average bias in measurements over all batches as a smooth function of sample mass, random variation in mass-related biases across batches, and mass-related heterogeneity in within-batch error variance. The model allowed partitioning the total variance of measured concentrations into the extraneous variances (due to different sample masses and laboratory batches) and the intrinsic variance (resulting from distinct metal exposures). We derived calibrated metal concentrations from the model by removing both sources of extraneous variation and estimating the predicted concentrations had all toenail samples been analyzed in a single batch and of the same mass. We provide the R script COMET (COrrected METals) to fit the proposed model, extract variance components, and calibrate metal concentrations. Results: In a multicase-control study in Spain (MCC-Spain) with toenail determinations for 16 metals in 4,473 incident cases of five common cancers and 3,450 population controls, sample mass and batch accounted for 26%-60% of the total variance of measured concentrations for most metals. In comparison with calibrated concentrations, odds ratios for measured concentrations were biased by >10% toward or away from the null in one-quarter of the estimated metal-cancer associations. Discussion: The proposed model allows correcting toenail metal concentrations for sample mass heterogeneity and between-batch variability and could be applied to other biological specimens of heterogeneous size, distinct laboratory techniques, and different study designs. https://doi.org/10.1289/EHP14784.

Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera).
Pubblicazione: Environmental health perspectives, 2025 (prima pubblicazione 2025-04-18).
Identificativi: PMID 40052947 · PMCID PMC12010933 · DOI 10.1289/ehp14784.
Descrittori MeSH principali: Nails; Metals; Environmental Pollutants; Environmental Exposure; Environmental Monitoring.
Pagina: https://europepmc.org/article/MED/40052947 — https://doi.org/10.1289/ehp14784. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0.
Letto il 2026-10-06T09:52:30.175Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.