Metraipolis › archive › dc_f7cc1ada1c6f
Optimal Estimation in Weak Value Amplification with a Position Pointer — arXiv:2611.00521
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.00521
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-03T11:46:48.838Z
- SHA-256 of the archived text
8351424b59c74ff96e1da7870c45c81fb53c7e28a7c6b9d0f93a33a018ba8b80- Stable URL of this page
https://metraipolis.com/documento/dc_f7cc1ada1c6f
How to cite
Optimal Estimation in Weak Value Amplification with a Position Pointer — arXiv:2611.00521 — arXiv (en), https://arxiv.org/abs/2611.00521 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f7cc1ada1c6f (Metraipolis archive dc_f7cc1ada1c6f, sha256 8351424b59c74ff96e1da7870c45c81fb53c7e28a7c6b9d0f93a33a018ba8b80)
BibTeX
@misc{dcf7cc1ada1c6f,
title = {Optimal Estimation in Weak Value Amplification with a Position Pointer — arXiv:2611.00521},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.00521},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f7cc1ada1c6f; sha256 8351424b59c74ff96e1da7870c45c81fb53c7e28a7c6b9d0f93a33a018ba8b80},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.00521. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
We experimentally evaluate five estimators for weak-value amplification (WVA) using a position pointer to measure birefringence time delays. Two general approaches are considered: measuring the position shift $\Delta x$ and measuring the probability change $\Delta P_w$ of successful postselection. Specifically, five estimators are investigated: CCD-detected fringe shift $\Delta x$, quadrant photodiode (PDQ) transversal voltage difference (XDIFF), and lock-in amplifier output phase $\eta$ (for $\Delta x$ measurement), as well as PDQ total output voltage (SUM) and CCD-detected average photon number $N_r$ (for $\Delta P_w$ measurement). The measurement precision is characterized by the Allan deviation over a range of input laser powers $P_0$. Generally, measuring the position shift $\Delta x$ yields higher precision than measuring the probability change $\Delta P_w$. At $P_0=0.5$~mW, corresponding to a laser-power-limited regime, direct measurement of the fringe displacement with the CCD achieves a minimum Allan deviation of $(5.30\pm0.10)\times10^{-3}$~as, approaching the corresponding photon-statistical Cramér--Rao bound (CRB). At $P_0=50$~mW, corresponding to a detector-limited regime, PDQ detection combined with lock-in demodulation provides the best precision, reaching $(1.80\pm0.06)\times10^{-3}$~as and remaining close to the corresponding CRB. These results demonstrate that the optimal readout depends on the available optical power, detector dynamic range, and technical noise, providing practical guidance for selecting readout strategies in high-precision WVA-based metrology.
Tema degli esploratori: fisica e astronomia (elenco arXiv quant-ph, nuovi lavori del giorno).
Categorie arXiv: Quantum Physics (quant-ph).
Pagina del lavoro: https://arxiv.org/abs/2611.00521 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-03T11:09:37.310Z dalla pagina https://arxiv.org/list/quant-ph/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).