Metraipolis › archive › dc_f77283c2d828

On the Degree of Safety: Beyond Safe or Unsafe with Control Barrier Functions — arXiv:2609.03319

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.03319
License (as archived)
CC0-1.0
Archived
2026-10-17T03:22:51.758Z
SHA-256 of the archived text
10931903b9ccbc3f9d105b67f9acacd905f4eed70fcfb80dba1d77e58977f3d5
Stable URL of this page
https://metraipolis.com/documento/dc_f77283c2d828

How to cite

On the Degree of Safety: Beyond Safe or Unsafe with Control Barrier Functions — arXiv:2609.03319 — arXiv (en), https://arxiv.org/abs/2609.03319 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f77283c2d828 (Metraipolis archive dc_f77283c2d828, sha256 10931903b9ccbc3f9d105b67f9acacd905f4eed70fcfb80dba1d77e58977f3d5)
BibTeX
@misc{dcf77283c2d828,
  title = {On the Degree of Safety: Beyond Safe or Unsafe with Control Barrier Functions — arXiv:2609.03319},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.03319},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f77283c2d828; sha256 10931903b9ccbc3f9d105b67f9acacd905f4eed70fcfb80dba1d77e58977f3d5},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.03319. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

A valid control barrier function (CBF) certifies if its represented safe set can be rendered forward invariant, and the sign of its value indicates whether a state is safe or not, but it does not quantify a degree of safety beyond the binary indication. In this paper, we show that among valid CBFs representing the same safe set, interior values and gradients can be changed arbitrarily, so neither quantity determines a degree of safety that is independent of how the set is represented. We also show that whether a candidate CBF-based inequality constraint is feasible does not by itself quantify a degree of safety. In particular, infeasibility can occur either because the safe set is not controlled invariant or because the candidate CBF representation fails. This motivates our distinction between intrinsic and representational infeasibility. Finally, we introduce the invariance authority demand (IAD), a representation-independent degree of safety that quantifies the control authority required for controlled invariance and can be used to guide set or actuator repair.

Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-04 in eess.SY).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2609.03319 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T03:08:49.842Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-04?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).