Metraipolis › archive › dc_f72ea422ab59
Tracker-Free Robotic Ultrasound Calibration with a Spherical-Marker Phantom and Threshold-Free Center Localization — arXiv:2609.22483
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.22483
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-09T22:21:17.554Z
- SHA-256 of the archived text
865dde3c028ffe881b95c322492e9e7f624e952503f6d0be688ce26bc5cdcd1f- Stable URL of this page
https://metraipolis.com/documento/dc_f72ea422ab59
How to cite
Tracker-Free Robotic Ultrasound Calibration with a Spherical-Marker Phantom and Threshold-Free Center Localization — arXiv:2609.22483 — arXiv (en), https://arxiv.org/abs/2609.22483 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f72ea422ab59 (Metraipolis archive dc_f72ea422ab59, sha256 865dde3c028ffe881b95c322492e9e7f624e952503f6d0be688ce26bc5cdcd1f)
BibTeX
@misc{dcf72ea422ab59,
title = {Tracker-Free Robotic Ultrasound Calibration with a Spherical-Marker Phantom and Threshold-Free Center Localization — arXiv:2609.22483},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.22483},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f72ea422ab59; sha256 865dde3c028ffe881b95c322492e9e7f624e952503f6d0be688ce26bc5cdcd1f},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.22483. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Robotic ultrasound (US) calibration is essential for accurately relating US images to the robot coordinate system, but accurate and automated calibration remains challenging because existing methods often require complex phantoms or external 3D trackers. In this work, we develop a tracker-free robotic US calibration framework using a spherical-marker phantom and a highly automated perception pipeline for sphere-center localization. The proposed threshold-free image-processing method localizes the spherical feature based on each US image's intensity distribution, eliminating hand-tuned intensity thresholds and improving robustness across imaging settings without per-system retuning. Multi-pose observations of the spherical fiducial are then used to estimate the US-to-EE transformation without external tracking or prior localization of the sphere center in the robot base frame. We validate the proposed framework on a robotic US platform through repeated sphere scans and further assess the calibrated system using geometrically distinct phantoms with known CAD models. Across 12 cross-validation folds, single-marker calibration achieved sphere-center accuracy and precision of $1.75\pm0.51$ mm and $0.85\pm0.11$ mm, respectively, compared with $1.72\pm0.51$ mm and $0.84\pm0.12$ mm for three-marker calibration. Across the three reconstruction sets, the single-marker calibration yielded pooled post-registration point-to-surface MAE$\pm$SD values of $0.41\pm0.35$ mm for the cone and $0.50\pm0.41$ mm for the triangular prism, closely matching the three-marker results of $0.40\pm0.35$ mm and $0.48\pm0.40$ mm, respectively. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-22 in cs.RO). Categorie arXiv: Robotics (cs.RO) ; Image and Video Processing (eess.IV). Pagina del lavoro: https://arxiv.org/abs/2609.22483 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-09T21:59:59.425Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-09-22?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).