Metraipolis › archive › dc_f67fe7fb011c

Integrating remote monitoring into heart failure patients' care regimen: A pilot study — Europe PMC PMID:33211733

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/33211733
DOI
10.1371/journal.pone.0242210
License (as archived)
CC0-1.0
Archived
2026-11-06T21:57:20.643Z
SHA-256 of the archived text
b72e51c3fd03d8421789a0717a3a5614828835d39a427162549ea2f4bb6a0b18
Stable URL of this page
https://metraipolis.com/documento/dc_f67fe7fb011c

How to cite

Integrating remote monitoring into heart failure patients' care regimen: A pilot study — Europe PMC PMID:33211733 — Europe PMC (en), https://europepmc.org/article/MED/33211733 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f67fe7fb011c (Metraipolis archive dc_f67fe7fb011c, sha256 b72e51c3fd03d8421789a0717a3a5614828835d39a427162549ea2f4bb6a0b18)
BibTeX
@misc{dcf67fe7fb011c,
  title = {Integrating remote monitoring into heart failure patients' care regimen: A pilot study — Europe PMC PMID:33211733},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/33211733},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f67fe7fb011c; sha256 b72e51c3fd03d8421789a0717a3a5614828835d39a427162549ea2f4bb6a0b18},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/33211733. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Background: Around 50% of hospital readmissions due to heart failure are preventable, with lack of adherence to prescribed self-care as a driving factor. Remote tracking and reminders issued by mobile health devices could help to promote self-care, which could potentially reduce these readmissions. Objective: We sought to investigate two factors: (1) feasibility of enrolling heart failure patients in a remote monitoring regimen that uses wireless sensors and patient-reported outcome measures; and (2) their adherence to using the study devices and completing patient-reported outcome measures. Methods: Twenty heart failure patients participated in piloting a remote monitoring regimen. Data collection included: (1) physical activity using wrist-worn activity trackers; (2) body weight using bathroom scales; (3) medication adherence using smart pill bottles; and (4) patient -reported outcomes using patient-reported outcome measures. Results: We evaluated 150 hospitalized heart failure patients and enrolled 20 individuals. Two factors contributed to 50% (65/130) being excluded from the study: smartphone ownership and patient discharge. Over the course of the study, 60.0% of the subjects wore the activity tracker for at least 70% of the hours, and 45.0% used the scale for more than 70% of the days. The pill bottle was used less than 10% of the days by 55.0% of the subjects. Conclusions: Our method of recruiting heart failure patients prior to hospital discharge may not be feasible as the enrollment rate was low. Once enrolled, the majority of subjects maintained a high adherence to wearing the activity tracker but low adherence to using the pill bottle and completing the follow-up surveys. Scale usage was fair, but it received positive reviews from most subjects. Given the observed usage and feedback, we suggest mobile health-driven interventions consider including an activity tracker and bathroom scale. We also recommend administering a shorter survey more regularly and through an easier interface.

Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera).
Pubblicazione: PloS one, 2020 (prima pubblicazione 2020-11-19).
Identificativi: PMID 33211733 · PMCID PMC7676713 · DOI 10.1371/journal.pone.0242210.