Metraipolis › archive › dc_f645633739e8

Optimal Estimation in Weak Value Amplification with a Position Pointer — arXiv:2611.00521

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.00521
License (as archived)
CC0-1.0
Archived
2026-11-03T19:00:50.400Z
SHA-256 of the archived text
a2077cd9cf8e4c10a736392a7780db1ed58d45da25885b94c55d01d59c804d69
Stable URL of this page
https://metraipolis.com/documento/dc_f645633739e8

How to cite

Optimal Estimation in Weak Value Amplification with a Position Pointer — arXiv:2611.00521 — arXiv (en), https://arxiv.org/abs/2611.00521 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f645633739e8 (Metraipolis archive dc_f645633739e8, sha256 a2077cd9cf8e4c10a736392a7780db1ed58d45da25885b94c55d01d59c804d69)
BibTeX
@misc{dcf645633739e8,
  title = {Optimal Estimation in Weak Value Amplification with a Position Pointer — arXiv:2611.00521},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.00521},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f645633739e8; sha256 a2077cd9cf8e4c10a736392a7780db1ed58d45da25885b94c55d01d59c804d69},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.00521. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

We experimentally evaluate five estimators for weak-value amplification (WVA) using a position pointer to measure birefringence time delays. Two general approaches are considered: measuring the position shift $\Delta x$ and measuring the probability change $\Delta P_w$ of successful postselection. Specifically, five estimators are investigated: CCD-detected fringe shift $\Delta x$, quadrant photodiode (PDQ) transversal voltage difference (XDIFF), and lock-in amplifier output phase $\eta$ (for $\Delta x$ measurement), as well as PDQ total output voltage (SUM) and CCD-detected average photon number $N_r$ (for $\Delta P_w$ measurement). The measurement precision is characterized by the Allan deviation over a range of input laser powers $P_0$. Generally, measuring the position shift $\Delta x$ yields higher precision than measuring the probability change $\Delta P_w$. At $P_0=0.5$~mW, corresponding to a laser-power-limited regime, direct measurement of the fringe displacement with the CCD achieves a minimum Allan deviation of $(5.30\pm0.10)\times10^{-3}$~as, approaching the corresponding photon-statistical Cramér--Rao bound (CRB). At $P_0=50$~mW, corresponding to a detector-limited regime, PDQ detection combined with lock-in demodulation provides the best precision, reaching $(1.80\pm0.06)\times10^{-3}$~as and remaining close to the corresponding CRB. These results demonstrate that the optimal readout depends on the available optical power, detector dynamic range, and technical noise, providing practical guidance for selecting readout strategies in high-precision WVA-based metrology.

Tema degli esploratori: fisica e astronomia (elenco arXiv quant-ph, nuovi lavori del giorno).
Categorie arXiv: Quantum Physics (quant-ph).
Pagina del lavoro: https://arxiv.org/abs/2611.00521 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-03T18:19:52.756Z dalla pagina https://arxiv.org/list/quant-ph/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).