Metraipolis › archive › dc_f58c2e6c97da

Task-Based CT Protocol Optimization Using Reinforcement Learning and Virtual Imaging Trials — arXiv:2609.13309

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.13309
License (as archived)
CC0-1.0
Archived
2026-10-15T22:48:23.166Z
SHA-256 of the archived text
79a35c6382f8b2784986225950bef85e4b986dac58075fee120653935b77c1cb
Stable URL of this page
https://metraipolis.com/documento/dc_f58c2e6c97da

How to cite

Task-Based CT Protocol Optimization Using Reinforcement Learning and Virtual Imaging Trials — arXiv:2609.13309 — arXiv (en), https://arxiv.org/abs/2609.13309 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f58c2e6c97da (Metraipolis archive dc_f58c2e6c97da, sha256 79a35c6382f8b2784986225950bef85e4b986dac58075fee120653935b77c1cb)
BibTeX
@misc{dcf58c2e6c97da,
  title = {Task-Based CT Protocol Optimization Using Reinforcement Learning and Virtual Imaging Trials — arXiv:2609.13309},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.13309},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f58c2e6c97da; sha256 79a35c6382f8b2784986225950bef85e4b986dac58075fee120653935b77c1cb},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.13309. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Protocol optimization in computed tomography (CT) aims to improve diagnostic image quality while reducing radiation dose, but the interdependence of acquisition and reconstruction parameters makes exhaustive testing impractical. We propose a virtual imaging trial framework with reinforcement learning for efficient CT protocol optimization. Sixty-three computational human models with liver lesions were imaged using a validated CT simulator across 468 combinations of acquisition and reconstruction parameters, including tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization objective balanced liver lesion detectability, quantified by detectability index d-prime, against radiation dose. A Proximal Policy Optimization agent was trained and conditioned on patient-specific CT localizer embeddings derived from a pretrained vision transformer. On held-out patients, evaluating only 8 protocols per patient, about 2% of exhaustive testing, recovered 98.2% of the exhaustive-search oracle objective. With no patient-specific simulation, surrogate scoring alone achieved 89.7% recovery. Conditioning on the localizer improved zero-simulation recovery by 10.7 percentage points over the localizer-blind policy (paired 95% CI 2.9-19.5; p=0.02). These results show that the proposed framework can substantially reduce exhaustive protocol testing while enabling task-based, dose-aware protocol selection before the diagnostic scan.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-15 in cs.AI).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI); Machine Learning (cs.LG).
Pagina del lavoro: https://arxiv.org/abs/2609.13309 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-15T22:29:03.450Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-15?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).