Metraipolis › archive › dc_f56eb99dd6f3

Uncertainty Quantification in Cardiac Model Personalisation from Ultrafast Ultrasound — arXiv:2609.35214

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.35214
License (as archived)
CC0-1.0
Archived
2026-10-07T22:41:08.907Z
SHA-256 of the archived text
e25a9b1149dfc95dadf49ad6733f05b11b362210fb861cbb91a5de157d4f0a0c
Stable URL of this page
https://metraipolis.com/documento/dc_f56eb99dd6f3

How to cite

Uncertainty Quantification in Cardiac Model Personalisation from Ultrafast Ultrasound — arXiv:2609.35214 — arXiv (en), https://arxiv.org/abs/2609.35214 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f56eb99dd6f3 (Metraipolis archive dc_f56eb99dd6f3, sha256 e25a9b1149dfc95dadf49ad6733f05b11b362210fb861cbb91a5de157d4f0a0c)
BibTeX
@misc{dcf56eb99dd6f3,
  title = {Uncertainty Quantification in Cardiac Model Personalisation from Ultrafast Ultrasound — arXiv:2609.35214},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.35214},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f56eb99dd6f3; sha256 e25a9b1149dfc95dadf49ad6733f05b11b362210fb861cbb91a5de157d4f0a0c},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.35214. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Cardiac model personalisation requires inferring mechanical parameters that are not directly measurable in vivo. Ultrafast ultrasound shear wave elastography (SWE) enables non-invasive tracking of myocardial stiffness dynamics over the cardiac cycle, providing a target for personalisation. However, mapping these observations to subject specific model parameters remains ill-posed, as multiple parameter sets can reproduce the same stiffness dynamics. We formulate SWE-informed personalisation as a statistical inference problem using simulation-based inference (SBI). Using a subject-adapted 0D cardiovascular model and neural posterior estimation, we estimate model-conditional posterior distributions over active stiffness scale k0, contraction rate kATP, and relaxation rate kSR, conditioned on SWE-derived curve features and subject specific context. Among six healthy volunteers, four passed objective prior-support diagnostics and were retained for quantitative posterior analysis. Curve-level RMSE against the observed SWE target decreased from 12.61 $\pm$ 5.55 kPa for the prior predictive median to 1.14 $\pm$ 0.38 kPa for the posterior predictive median, an 89.7 $\pm$ 4.2% reduction. Posterior analysis revealed parameter-specific uncertainty, k0-kATP compensation, weaker constraint of kSR, and the importance of prior-predictive diagnostics for assessing whether each subject is represented within the modelled SWE feature space. These results support SBI for uncertainty aware SWE-based personalisation, while identifying prior support and forward-model adequacy as key diagnostics.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-29 in cs.LG).
Categorie arXiv: Quantitative Methods (q-bio.QM) ; Machine Learning (cs.LG); Medical Physics (physics.med-ph).
Pagina del lavoro: https://arxiv.org/abs/2609.35214 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T22:14:28.909Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).