Metraipolis › archive › dc_f4fe982dd6e2
Development of a Temperature-Variable Cold Blackbody Calibrator for Millimeter and Submillimeter Wave Detectors — arXiv:2609.21473
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.21473
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-10T03:04:37.318Z
- SHA-256 of the archived text
f36a53b90df2ca924868305d7e8ccca4ea6fd2cd5e53fcea53b7ffb2ab3f5be2- Stable URL of this page
https://metraipolis.com/documento/dc_f4fe982dd6e2
How to cite
Development of a Temperature-Variable Cold Blackbody Calibrator for Millimeter and Submillimeter Wave Detectors — arXiv:2609.21473 — arXiv (en), https://arxiv.org/abs/2609.21473 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f4fe982dd6e2 (Metraipolis archive dc_f4fe982dd6e2, sha256 f36a53b90df2ca924868305d7e8ccca4ea6fd2cd5e53fcea53b7ffb2ab3f5be2)
BibTeX
@misc{dcf4fe982dd6e2,
title = {Development of a Temperature-Variable Cold Blackbody Calibrator for Millimeter and Submillimeter Wave Detectors — arXiv:2609.21473},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.21473},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f4fe982dd6e2; sha256 f36a53b90df2ca924868305d7e8ccca4ea6fd2cd5e53fcea53b7ffb2ab3f5be2},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.21473. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
We report the design, fabrication, and characterization of a cryogenic blackbody calibrator intended for laboratory-based detector characterization, providing multi-temperature calibration of millimeter- and submillimeter-wave detectors over a temperature range of 4 K to ~10 K. The device employs a Stycast/SiC absorber shaped for uniform array illumination and mounted on a phosphor-bronze substrate with optimized thermal links. Measured thermal conductance and heat capacity show the expected temperature dependence, although the conductance was lower than estimated, yielding a thermal time constant of 8.5 s at 10 K versus the 3.7 s design estimate. The response remains practical, demonstrating the calibrator's effectiveness as a stable reference source for precise calibration of detector arrays. Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-21 in astro-ph.IM). Categorie arXiv: Instrumentation and Methods for Astrophysics (astro-ph.IM) ; Instrumentation and Detectors (physics.ins-det). Pagina del lavoro: https://arxiv.org/abs/2609.21473 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-10T02:42:39.366Z dalla pagina https://arxiv.org/catchup/astro-ph.IM/2026-09-21?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).