Metraipolis › archive › dc_f470e7cb581b
The PreQuine Platform: A novel diagnostic tool for measuring glucose-6-phosphate dehydrogenase (G6PD) activity and hemoglobin concentration — Europe PMC PMID:38728310
- Source
- Europe PMC (en)
- Original
- https://europepmc.org/article/MED/38728310
- DOI
- 10.1371/journal.pone.0297918
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-06T18:31:41.842Z
- SHA-256 of the archived text
3d6d2c77e0f5f2a8b8b7e2737b9ac76247081c224da1671a21bf0410737a6d16- Stable URL of this page
https://metraipolis.com/documento/dc_f470e7cb581b
How to cite
The PreQuine Platform: A novel diagnostic tool for measuring glucose-6-phosphate dehydrogenase (G6PD) activity and hemoglobin concentration — Europe PMC PMID:38728310 — Europe PMC (en), https://europepmc.org/article/MED/38728310 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f470e7cb581b (Metraipolis archive dc_f470e7cb581b, sha256 3d6d2c77e0f5f2a8b8b7e2737b9ac76247081c224da1671a21bf0410737a6d16)
BibTeX
@misc{dcf470e7cb581b,
title = {The PreQuine Platform: A novel diagnostic tool for measuring glucose-6-phosphate dehydrogenase (G6PD) activity and hemoglobin concentration — Europe PMC PMID:38728310},
howpublished = {Europe PMC (en)},
url = {https://europepmc.org/article/MED/38728310},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f470e7cb581b; sha256 3d6d2c77e0f5f2a8b8b7e2737b9ac76247081c224da1671a21bf0410737a6d16},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/38728310. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Quantitative diagnosis of glucose-6-phosphate dehydrogenase (G6PD) deficiency is essential for the safe administration of 8-aminoquinoline based radical cure for the treatment of Plasmodium vivax infections. Here, we present the PreQuine Platform (IVDS, USA), a quantitative biosensor that uses a dual-analyte assay for the simultaneous measurement of Hemoglobin (Hgb) levels and G6PD enzyme activity within the same sample. The platform relies on a downloadable mobile application. The device requires 10μl of whole blood and works with a reflectance-based meter. Comparing the G6PD measurement normalized by Hgb of 12 samples from the PreQuine Platform with reference measurements methods (spectrophotometry, Pointe Scientific, USA and hemoglobin meter, HemoCue, Sweden) showed a positive and significant agreement with a slope of 1.0091 and an intercept of -0.0379 under laboratory conditions. Next steps will be to conduct field trials in Bangladesh, Cambodia, and the USA to assess diagnostic performance, user friendliness and acceptance. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera). Pubblicazione: PloS one, 2024 (prima pubblicazione 2024-05-10). Identificativi: PMID 38728310 · PMCID PMC11086878 · DOI 10.1371/journal.pone.0297918. Descrittori MeSH principali: Glucosephosphate Dehydrogenase Deficiency; Glucosephosphate Dehydrogenase; Hemoglobins. Pagina: https://europepmc.org/article/MED/38728310 — https://doi.org/10.1371/journal.pone.0297918. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0. Letto il 2026-10-06T16:55:36.222Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.