Metraipolis › archive › dc_f3dbe6ea0294

Object-Centered Reconstruction for Vision-Based 3D Force Estimation — arXiv:2609.23856

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.23856
License (as archived)
CC0-1.0
Archived
2026-10-09T22:24:06.894Z
SHA-256 of the archived text
a3451c32992a6f883872db6fb12d72d72c46975989997da196c837ba2b410419
Stable URL of this page
https://metraipolis.com/documento/dc_f3dbe6ea0294

How to cite

Object-Centered Reconstruction for Vision-Based 3D Force Estimation — arXiv:2609.23856 — arXiv (en), https://arxiv.org/abs/2609.23856 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f3dbe6ea0294 (Metraipolis archive dc_f3dbe6ea0294, sha256 a3451c32992a6f883872db6fb12d72d72c46975989997da196c837ba2b410419)
BibTeX
@misc{dcf3dbe6ea0294,
  title = {Object-Centered Reconstruction for Vision-Based 3D Force Estimation — arXiv:2609.23856},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.23856},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f3dbe6ea0294; sha256 a3451c32992a6f883872db6fb12d72d72c46975989997da196c837ba2b410419},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.23856. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Excessive force may damage tissue and increase the risk of anastomotic leakage in robotic colorectal surgery. Although the da Vinci 5 provides force sensing, this capability is unavailable on earlier da Vinci systems and many other surgical robotic platforms. In this work, we present a vision-based pipeline for estimating 3D interaction forces from soft-tissue deformation in stereo endoscopic video. We dynamically reconstruct the tissue point cloud in an object-centered coordinate frame, track tissue points with geometric constraints, and predict the 3D force vector with a neural network. We progressively evaluate the pipeline on rubber-glove phantoms, ex vivo porcine colons, and in vivo colorectal surgical video sequences. Under varying tissue orientations and positions within the endoscopic view, as well as different camera viewpoints, the proposed method achieves average root mean square error (RMSEs) of 0.77 N and 1.30 N on the phantom and porcine colon, respectively. Compared with the camera-frame representation, the object-centered representation reduces average RMSE by 51.3% and 56.7%, while geometry-constrained tracking reduces RMSE by 19.8% and 25.3% compared with CoTracker. We further qualitatively demonstrate the feasibility of vision-based force estimation on an in vivo colorectal surgical sequence, as a step toward clinical translation of vision-based, sensorless force estimation.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-22 in cs.RO).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2609.23856 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-09T21:59:59.634Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-09-22?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).