Metraipolis › archive › dc_f375a668c585

An Uncertainty-Guided Digital Twin Framework for Online Adaptive Proton Therapy in Head and Neck Cancer: A Feasibility Study — arXiv:2609.39010

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.39010
License (as archived)
CC0-1.0
Archived
2026-10-07T12:44:44.389Z
SHA-256 of the archived text
9a2ffaa407f8621578dc9b22791098305c0700806b8a69c36229d8823c571dae
Stable URL of this page
https://metraipolis.com/documento/dc_f375a668c585

How to cite

An Uncertainty-Guided Digital Twin Framework for Online Adaptive Proton Therapy in Head and Neck Cancer: A Feasibility Study — arXiv:2609.39010 — arXiv (en), https://arxiv.org/abs/2609.39010 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f375a668c585 (Metraipolis archive dc_f375a668c585, sha256 9a2ffaa407f8621578dc9b22791098305c0700806b8a69c36229d8823c571dae)
BibTeX
@misc{dcf375a668c585,
  title = {An Uncertainty-Guided Digital Twin Framework for Online Adaptive Proton Therapy in Head and Neck Cancer: A Feasibility Study — arXiv:2609.39010},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.39010},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f375a668c585; sha256 9a2ffaa407f8621578dc9b22791098305c0700806b8a69c36229d8823c571dae},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.39010. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Objective: Head and neck (HN) proton therapy spans six to seven weeks of anatomical change, while offline replanning takes about a week. We present an uncertainty-guided digital twin (UGDT) framework that forecasts treatment-day anatomy before treatment and evaluate whether it generates online adaptive proton therapy (APT) plans of clinical quality. Approach: A library of 302 longitudinal deformations from 88 previously treated HN patients was transported onto each new patient's treatment planning CT (TPCT) using two-step multi-atlas deformable image registration (DIR) built on a pretrained CT foundation model, generating about 284 predicted CTs (pdCTs) with contours per patient. Dispersion of propagated clinical target volume (CTV) contours defined a patient-specific robust margin. In ten patients, the quality assurance CT (QACT) triggering a replan represented treatment-day anatomy, and the physician-approved replan was the baseline. The pdCT most similar to the QACT (pdCT-H) and one from the lowest quartile (pdCT-L) were planned to within about 5% of baseline plan quality, forward-calculated on the QACT, and reoptimized to generate online APT plans. Main results: pdCT plans scored within -0.7% (pdCT-H) and -1.0% (pdCT-L) of baseline. Forward calculation on QACT reduced high-dose CTV D98% to 88.3% and 85.5%. After online reoptimization, D98% recovered to 98.3 +/- 0.3% and 98.2 +/- 0.3%, versus 98.5 +/- 0.4% at baseline. Spinal cord and brainstem doses remained below tolerance, and plan quality scores were within -1.1% (p = 0.19) and -1.7% (p = 0.01) of baseline. Significance: UGDT generated online APT plans comparable in quality to physician-approved offline replans using anatomy forecast before treatment, enabling a transition from reactive offline replanning toward anticipatory online adaptation.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-10-01 in cs.AI).
Categorie arXiv: Medical Physics (physics.med-ph) ; Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2609.39010 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T12:14:13.996Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-10-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).