Metraipolis › archive › dc_f3441ac1c416

3D CT-to-PET Translation via Latent Brownian Bridge Diffusion — arXiv:2609.12860

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.12860
License (as archived)
CC0-1.0
Archived
2026-10-16T03:03:38.988Z
SHA-256 of the archived text
92574f52baa458cb404d7d7cf0e34f59fc9e8c6b1cabac11f8533447e59372c0
Stable URL of this page
https://metraipolis.com/documento/dc_f3441ac1c416

How to cite

3D CT-to-PET Translation via Latent Brownian Bridge Diffusion — arXiv:2609.12860 — arXiv (en), https://arxiv.org/abs/2609.12860 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f3441ac1c416 (Metraipolis archive dc_f3441ac1c416, sha256 92574f52baa458cb404d7d7cf0e34f59fc9e8c6b1cabac11f8533447e59372c0)
BibTeX
@misc{dcf3441ac1c416,
  title = {3D CT-to-PET Translation via Latent Brownian Bridge Diffusion — arXiv:2609.12860},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.12860},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f3441ac1c416; sha256 92574f52baa458cb404d7d7cf0e34f59fc9e8c6b1cabac11f8533447e59372c0},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.12860. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Computed tomography (CT) and positron emission tomography (PET) provide complementary anatomical and functional information for cancer diagnosis and treatment planning. However, the widespread use of PET is limited by high radiation exposure, elevated costs, and restricted availability. To address these limitations, deep learning-based CT-to-PET translation has emerged as a promising approach for synthesizing PET-like information directly from CT images, although accurately modeling the large cross-modal gap remains challenging. In this work, we propose a 3D CT-to-PET translation framework based on latent Brownian Bridge Diffusion (BBDM). The method consists of two stages. First, a Variational Autoencoder (VAE) is trained on paired CT-PET patches, integrating contrastive learning to improve latent alignment between anatomical and metabolic representations. Second, a BBDM is trained in the latent space to translate CT latent representations into their corresponding PET counterparts. The translated PET latents are then decoded and stitched to reconstruct the final 3D PET volume. We evaluate the proposed approach on two publicly available datasets. Quantitative results based on image fidelity and lesion-level PET-specific metrics demonstrate improved performance compared with competing methods. In particular, the proposed approach improves PET signal fidelity, better preserves clinically relevant uptake patterns, and shows improved performance in preserving small-lesion metabolic activation, paving the way for virtual imaging applications.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-14 in cs.AI).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2609.12860 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T02:51:27.948Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-14?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).