Metraipolis › archive › dc_f33068a7561e

Improving the Realism of Synthetic Clinical Benchmarks Under Utility Constraints — arXiv:2608.06265

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.06265
License (as archived)
CC0-1.0
Archived
2026-10-31T10:50:03.860Z
SHA-256 of the archived text
be6b468fb69a994af65632926ee74e8430d58144fed2a8ba56690d43539d88f7
Stable URL of this page
https://metraipolis.com/documento/dc_f33068a7561e

How to cite

Improving the Realism of Synthetic Clinical Benchmarks Under Utility Constraints — arXiv:2608.06265 — arXiv (en), https://arxiv.org/abs/2608.06265 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f33068a7561e (Metraipolis archive dc_f33068a7561e, sha256 be6b468fb69a994af65632926ee74e8430d58144fed2a8ba56690d43539d88f7)
BibTeX
@misc{dcf33068a7561e,
  title = {Improving the Realism of Synthetic Clinical Benchmarks Under Utility Constraints — arXiv:2608.06265},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.06265},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f33068a7561e; sha256 be6b468fb69a994af65632926ee74e8430d58144fed2a8ba56690d43539d88f7},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.06265. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Synthetic clinical benchmarks for enterprise AI agents can pass existing utility checks and still remain structurally unrealistic, especially in privacy-sensitive healthcare settings where operational data are hard to access. We study how to improve such benchmarks without breaking the downstream utility checks already used in practice. We formulate benchmark revision as utility-constrained realism improvement: dataset changes should increase realism while staying above an operational utility floor. We instantiate this idea on a care-gap benchmark derived from Synthea-generated patients exercised through demonstration electronic health record workflows and then processed by the same downstream pipeline as operational data. Realism is measured through missingness structure, simplicity, structural plausibility, and population alignment. The baseline benchmark is extremely thin: sampled-pair missingness is 79.44%, only 12.75% of rows are actionable, 38.94% of patients have zero actionable measures, and top-three token concentration reaches 100.0%. Two deterministic revisions improve these panels while remaining above the current utility floor, whereas a naive densification control preserves unrealistic templating. We further show that internal benchmark realism and source fidelity to an aggregate operational reference are related but distinct objectives. These results suggest that synthetic benchmark quality should be optimized explicitly, with utility treated as one constraint rather than as sufficient evidence of realism.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-07 in cs.DB).
Categorie arXiv: Artificial Intelligence (cs.AI) ; Databases (cs.DB); Machine Learning (cs.LG).
Pagina del lavoro: https://arxiv.org/abs/2608.06265 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-31T10:36:13.373Z dalla pagina https://arxiv.org/catchup/cs.DB/2026-08-07?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).