Metraipolis › archive › dc_f284c9c8a6a7

Preserving Anatomical Continuity: Three-Stage Pipeline for Colon Segmentation in 3D Abdominal CT Scans — arXiv:2610.03467

Source
arXiv
Original
https://arxiv.org/abs/2610.03467
License (as archived)
CC0-1.0
Archived
2026-10-05T22:50:41.237Z
SHA-256 of the archived text
df78a335b06e898cd7767a599cd7a6206b71c26859f35756f4c4239891e3eaeb
Stable URL of this page
https://metraipolis.com/documento/dc_f284c9c8a6a7

How to cite

Preserving Anatomical Continuity: Three-Stage Pipeline for Colon Segmentation in 3D Abdominal CT Scans — arXiv:2610.03467 — arXiv, https://arxiv.org/abs/2610.03467 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f284c9c8a6a7 (Metraipolis archive dc_f284c9c8a6a7, sha256 df78a335b06e898cd7767a599cd7a6206b71c26859f35756f4c4239891e3eaeb)
BibTeX
@misc{dcf284c9c8a6a7,
  title = {Preserving Anatomical Continuity: Three-Stage Pipeline for Colon Segmentation in 3D Abdominal CT Scans — arXiv:2610.03467},
  howpublished = {arXiv},
  url = {https://arxiv.org/abs/2610.03467},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f284c9c8a6a7; sha256 df78a335b06e898cd7767a599cd7a6206b71c26859f35756f4c4239891e3eaeb},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv, https://arxiv.org/abs/2610.03467. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Accurate colon segmentation from CT images is essential for colorectal disease analysis, yet deep learning based methods often produce disconnected predictions due to complex anatomy. This study introduces a three-stage, topology-preserving segmentation pipeline to address this issue. The first stage performs initial deep learning-based segmentation, followed by centreline bridging to reconnect disjoint regions and a reconstruction stage to refine continuity. Evaluations on TotalSegmentator and RAOS datasets using overlap, distance and topology-based metrics demonstrate improved structural consistency while maintaining segmentation accuracy. The proposed method enhances topological integrity, enabling more reliable colon segmentation for clinical and research applications.

Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.AI, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2610.03467 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-05T22:45:55.865Z dalla pagina https://arxiv.org/list/cs.AI/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).