Metraipolis › archive › dc_f257d7ef71b5
Artifact removal improves electrodermal waveforms but not downstream classification in a virtual-reality balance task — arXiv:2610.07438
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.07438
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-07T11:39:21.881Z
- SHA-256 of the archived text
72de171469a43afd11f8082051a058524479c8b08f20c119af64e7f75c69d495- Stable URL of this page
https://metraipolis.com/documento/dc_f257d7ef71b5
How to cite
Artifact removal improves electrodermal waveforms but not downstream classification in a virtual-reality balance task — arXiv:2610.07438 — arXiv (en), https://arxiv.org/abs/2610.07438 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f257d7ef71b5 (Metraipolis archive dc_f257d7ef71b5, sha256 72de171469a43afd11f8082051a058524479c8b08f20c119af64e7f75c69d495)
BibTeX
@misc{dcf257d7ef71b5,
title = {Artifact removal improves electrodermal waveforms but not downstream classification in a virtual-reality balance task — arXiv:2610.07438},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.07438},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f257d7ef71b5; sha256 72de171469a43afd11f8082051a058524479c8b08f20c119af64e7f75c69d495},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.07438. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Artifact removal routinely precedes the classification of electrodermal activity (EDA), on the assumption that a cleaner signal supports a better decision. We tested this assumption in a virtual-reality (VR) balance-disturbance task. A residual gating network was trained on a benchmark with expert-corrected EDA, frozen, and applied to VR recordings, where raw and gated signals were classified by five published time-series methods under identical leave-one-participant-out evaluation. On the benchmark the gate detected artifacts well (median record AUROC 0.94) and reduced error inside artifact regions by 17.8%. In the VR task it did not improve classification. Changes in balanced accuracy ranged from -1.35 to +0.93 percentage points, no classifier improved and two lost accuracy, and all five were equivalent to raw input within +/- 3.32 points. The benefit was lost between waveform and decision. The correction that lowered waveform error also reduced skin conductance response detection in all 43 benchmark records. Processing left 92.8% of predictions unchanged, and the predictions it did change were corrected and corrupted at similar rates. The VR recordings also carried little contamination (an estimated 4.6% of samples), and even perfect localization of deliberately injected artifacts recovered only 3.3 points in the most sensitive classifier. A pooled association between artifact level and accuracy (11.3 points) disappeared within participants (0.1 points), showing how differences between people can make cleaning look useful. Preprocessing should be judged by the decision it supports, against an unprocessed arm. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.HC, nuovi lavori del giorno). Categorie arXiv: Human-Computer Interaction (cs.HC) ; Machine Learning (cs.LG); Signal Processing (eess.SP). Pagina del lavoro: https://arxiv.org/abs/2610.07438 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-07T11:19:09.631Z dalla pagina https://arxiv.org/list/cs.HC/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).