Metraipolis › archive › dc_f1ee0c27fc50

A multicenter benchmark and clinically structured metric for coronary CTA report generation — arXiv:2609.00909

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.00909
License (as archived)
CC0-1.0
Archived
2026-10-17T07:13:40.979Z
SHA-256 of the archived text
fab8d602065f880aba139d743f66bb6c798a1d75ef350eab85e8794667196816
Stable URL of this page
https://metraipolis.com/documento/dc_f1ee0c27fc50

How to cite

A multicenter benchmark and clinically structured metric for coronary CTA report generation — arXiv:2609.00909 — arXiv (en), https://arxiv.org/abs/2609.00909 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_f1ee0c27fc50 (Metraipolis archive dc_f1ee0c27fc50, sha256 fab8d602065f880aba139d743f66bb6c798a1d75ef350eab85e8794667196816)
BibTeX
@misc{dcf1ee0c27fc50,
  title = {A multicenter benchmark and clinically structured metric for coronary CTA report generation — arXiv:2609.00909},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.00909},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_f1ee0c27fc50; sha256 fab8d602065f880aba139d743f66bb6c798a1d75ef350eab85e8794667196816},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.00909. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Reliable evaluation of automated coronary computed tomography angiography (CCTA) report generation requires standardized multicentre benchmarks and clinically structured metrics. We established a four-centre benchmark comprising 3,021 CCTA series from 818 patient-report pairs to evaluate seven open-source three-dimensional vision-language models. We developed CSM$_{\text{CCTA}}$, a clinically structured metric for CCTA report evaluation, with patient-, vessel-, and segment-level variables defined according to clinical guidelines. Report pairs are compared at the finest shared anatomical level, and the contributions of different clinical components are weighted based on expert assessments. We estimated these weights using 70 expert-scored cases and evaluated clinical alignment in a non-overlapping set of 30 cases. CSM$_{\text{CCTA}}$ showed a strong correlation with radiologist scores (Pearson's $r=0.97$, $p<0.001$), exceeding the next-best metric, FORTE ($r=0.70$), by 0.27, and agreed with expert preferences in 115 of 160 pairwise comparisons (71.9\%). Under controlled perturbations, CSM$_{\text{CCTA}}$ remained stable to clinically equivalent wording and decreased monotonically with progressive information omission. In the multicenter benchmark, the CCTA-trained C2RG model achieved the highest CSM$_{\text{CCTA}}$ scores across all four hospitals, although its performance remained far from optimal. In contrast, CCTA-irrelevant reports accounted for up to 98.7\% of the outputs from generalist models. Together, the benchmark provides a standardized setting for model comparison, while CSM$_{\text{CCTA}}$ enables clinically structured evaluation of finding agreement and anatomical specificity. These results support a more clinically aligned and anatomically resolved approach to evaluating CCTA report generation. Code is available at this https URL .

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-02 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.00909 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T07:00:58.943Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-02?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).