Metraipolis › archive › dc_efea41cfd589

Design Considerations to Improve Charpy Instrumented Strikers — Europe PMC PMID:36474860

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/36474860
DOI
10.6028/jres.125.010
License (as archived)
CC0-1.0
Archived
2026-11-09T05:27:44.776Z
SHA-256 of the archived text
6605344f49190493af079ddbeefcbd686aa70892261e7d2eb2e46f83309e111e
Stable URL of this page
https://metraipolis.com/documento/dc_efea41cfd589

How to cite

Design Considerations to Improve Charpy Instrumented Strikers — Europe PMC PMID:36474860 — Europe PMC (en), https://europepmc.org/article/MED/36474860 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_efea41cfd589 (Metraipolis archive dc_efea41cfd589, sha256 6605344f49190493af079ddbeefcbd686aa70892261e7d2eb2e46f83309e111e)
BibTeX
@misc{dcefea41cfd589,
  title = {Design Considerations to Improve Charpy Instrumented Strikers — Europe PMC PMID:36474860},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/36474860},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_efea41cfd589; sha256 6605344f49190493af079ddbeefcbd686aa70892261e7d2eb2e46f83309e111e},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/36474860. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Instrumented impact testing allows the applicability of conventional Charpy tests to be extended toward assessing mechanical properties such as dynamic fracture toughness and dynamic tensile properties. In this work, we present design considerations for engineering instrumented strikers for Charpy V-notch impact testing. Specific attention is given to the mechanical and geometric features, as well as the placement of strain gauges and corresponding bridge circuits for instrumentation. These design considerations are intended to make the sensitivity invariant to the location and distribution of impact forces. The concepts presented in this work were applied to an actual instrumented striker, which was then statically calibrated. Data from this calibration indicate that the device has good repeatability, shows a linear response, and is relatively insensitive to impact location.

Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera).
Pubblicazione: Journal of research of the National Institute of Standards and Technology, 2020 (prima pubblicazione 2020-03-16).
Identificativi: PMID 36474860 · PMCID PMC9704991 · DOI 10.6028/jres.125.010.
Parole chiave degli autori: Fracture Mechanics; Dynamic Force; Instrumented Striker; Charpy; Instrumented Charpy Testing.
Pagina: https://europepmc.org/article/MED/36474860 — https://doi.org/10.6028/jres.125.010. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0.
Letto il 2026-11-09T05:24:26.209Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.