Metraipolis › archive › dc_efa3abda25d7
Distributed Cooperative Control with Prescribed Performance of BESSs with A Unified Discharge Constrain for Power Allocation under Dynamic Load — arXiv:2609.22889
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.22889
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-10T00:55:17.416Z
- SHA-256 of the archived text
6cd9d33179ba2006360a600d96dda23354675bd19f394e46daeeeadacb06d60f- Stable URL of this page
https://metraipolis.com/documento/dc_efa3abda25d7
How to cite
Distributed Cooperative Control with Prescribed Performance of BESSs with A Unified Discharge Constrain for Power Allocation under Dynamic Load — arXiv:2609.22889 — arXiv (en), https://arxiv.org/abs/2609.22889 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_efa3abda25d7 (Metraipolis archive dc_efa3abda25d7, sha256 6cd9d33179ba2006360a600d96dda23354675bd19f394e46daeeeadacb06d60f)
BibTeX
@misc{dcefa3abda25d7,
title = {Distributed Cooperative Control with Prescribed Performance of BESSs with A Unified Discharge Constrain for Power Allocation under Dynamic Load — arXiv:2609.22889},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.22889},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_efa3abda25d7; sha256 6cd9d33179ba2006360a600d96dda23354675bd19f394e46daeeeadacb06d60f},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.22889. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Battery energy storage system (BESS) is integrated into the smart grid to enhance scalability, economy, and greenery. And the State-of-Charge (SoC) balance is one of the basic problems of BESSs, which can maximize the utilization of capacity. BESSs with a unified relative variation rate for SoC can be simultaneously filled or empty, while real-time estimation schemes of SoC balance and power sharing states are required in this power allocation scheme. Therefore, the prescribed performance control (PPC) method is applied in this paper to design two distributed estimators based on multi-agent systems (MASs), in order to estimate the power sharing and SoC balance states in real-time under dynamic load driving. In this way, these two average values can ultimately be well estimated with almost zero error performance, and dynamic performance and steady-state performance of the two estimators can be adjusted by different parameters. Similarly, consensus performance and dynamic tracking performance are decoupled. These results provide a broader range for the selection of gains. To verify the effectiveness, robustness and progressiveness of the designed estimators, some cases with a resistance network containing 4 BESSs as load distribution are designed and discussed. Further more, to test scalability, a large-scale system containing 12 BESSs is conducted to the designed scheme. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-22 in eess.SY). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2609.22889 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-09T23:57:37.598Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-22?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).