Metraipolis › archive › dc_eedac13748b2

Nonequilibrium pulse dynamics and metastable latching in nonlinear kinetic inductance detectors — arXiv:2608.23902

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.23902
License (as archived)
CC0-1.0
Archived
2026-10-18T07:20:57.833Z
SHA-256 of the archived text
c893f2506c1fe6465b5ca8ed311146f0c3ccf3bada8a078c349f9884831d85e2
Stable URL of this page
https://metraipolis.com/documento/dc_eedac13748b2

How to cite

Nonequilibrium pulse dynamics and metastable latching in nonlinear kinetic inductance detectors — arXiv:2608.23902 — arXiv (en), https://arxiv.org/abs/2608.23902 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_eedac13748b2 (Metraipolis archive dc_eedac13748b2, sha256 c893f2506c1fe6465b5ca8ed311146f0c3ccf3bada8a078c349f9884831d85e2)
BibTeX
@misc{dceedac13748b2,
  title = {Nonequilibrium pulse dynamics and metastable latching in nonlinear kinetic inductance detectors — arXiv:2608.23902},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.23902},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_eedac13748b2; sha256 c893f2506c1fe6465b5ca8ed311146f0c3ccf3bada8a078c349f9884831d85e2},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.23902. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Microwave kinetic inductance detectors are typically operated at high readout power to raise the detector signal above system noise. At sufficiently large readout power, the current-dependent kinetic inductance couples the detector response to its readout bias. Using a nonlinear resonator framework and time-domain circuit calculations, we show that the amplitude, shape, and relaxation time of the driven detector's response depend on both the absorbed energy and on the readout bias. Strongly driven bias points produce amplified, extended, and non-exponential pulse responses. Qualitative agreement between calculated and measured pulse responses indicates that these effects are dominated by the driven nonlinear resonator dynamics rather than by altered quasiparticle dynamics. Beyond resonance bifurcation, sufficiently large pulse events drive the resonator between stable branches, resulting in a metastable latched state which persists after the quasiparticle transient has decayed. The pulse energy required for branch switching is set by the readout bias, suggesting a mode of triggered detection with an in-situ tunable threshold. Although nonlinear operation requires calibration of the bias- and energy-dependent response, the enhanced pulse amplitude and duration, together with tunable latching and the ability to select these parameters via the readout operating state, are likely to be of interest for single-photon and rare-event experiments, especially those limited by amplifier or system noise.

Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-08-26 in astro-ph.IM).
Categorie arXiv: Superconductivity (cond-mat.supr-con) ; Instrumentation and Methods for Astrophysics (astro-ph.IM).
Pagina del lavoro: https://arxiv.org/abs/2608.23902 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-18T07:17:53.125Z dalla pagina https://arxiv.org/catchup/astro-ph.IM/2026-08-26?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).