Metraipolis › archive › dc_ee92008fc36b
Voltage Stability Assessment with Path-Coupled Load Growth and Corrective Generator Response — arXiv:2608.15122
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.15122
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-19T02:13:21.487Z
- SHA-256 of the archived text
4ab6ece1957bab188e25c9f082722e9b2aa8976fb1435e4b3ceb31061f0f64b3- Stable URL of this page
https://metraipolis.com/documento/dc_ee92008fc36b
How to cite
Voltage Stability Assessment with Path-Coupled Load Growth and Corrective Generator Response — arXiv:2608.15122 — arXiv (en), https://arxiv.org/abs/2608.15122 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ee92008fc36b (Metraipolis archive dc_ee92008fc36b, sha256 4ab6ece1957bab188e25c9f082722e9b2aa8976fb1435e4b3ceb31061f0f64b3)
BibTeX
@misc{dcee92008fc36b,
title = {Voltage Stability Assessment with Path-Coupled Load Growth and Corrective Generator Response — arXiv:2608.15122},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.15122},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ee92008fc36b; sha256 4ab6ece1957bab188e25c9f082722e9b2aa8976fb1435e4b3ceb31061f0f64b3},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.15122. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Voltage stability margin assessment is essential for the secure operation of renewable-dominated power systems. Conventional continuation-based methods evaluate the margin along predefined load-growth paths with fixed generator partic- ipation, while practical operation allows generators to be redis- patched to alleviate voltage stress and reshape the power-flow trajectory as the system approaches voltage collapse. This paper proposes a path-coupled margin assessment approach that incor- porates corrective generator response into static voltage stability margin assessment. In the proposed approach, the load-growth direction and generator response direction are simultaneously determined at each continuation step, enabling the assessment trajectory to account for generator response while tracing the system toward voltage collapse. The voltage stability margin is then evaluated by the cumulative active load increase along this coupled trajectory. Based on the obtained trajectory and collapse point, a feasible redispatch direction is further derived to improve the margin of the current operating state. The economic cost of voltage stability enhancement is quantified through a marginal stability cost, providing an economic indicator for additional sta- bility support. Case studies on various test systems demonstrate that the proposed framework can effectively capture the impact of corrective generator redispatch on voltage stability assessment, provide effective guidance for margin enhancement, and quantify the cost associated with voltage stability improvement. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-08-18 in eess.SY). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2608.15122 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-19T01:24:59.538Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-08-18?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).