Metraipolis › archive › dc_ed26e890bdce

PelviNeXt: A Modality-Agnostic Hybrid Network for Pelvic Imaging in Women's Health — arXiv:2608.20144

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.20144
License (as archived)
CC0-1.0
Archived
2026-10-18T12:04:48.555Z
SHA-256 of the archived text
819b612977b8eeda9acb88917e9e86b9eb7cb83c5cfdf3e74d845493c12eb772
Stable URL of this page
https://metraipolis.com/documento/dc_ed26e890bdce

How to cite

PelviNeXt: A Modality-Agnostic Hybrid Network for Pelvic Imaging in Women's Health — arXiv:2608.20144 — arXiv (en), https://arxiv.org/abs/2608.20144 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ed26e890bdce (Metraipolis archive dc_ed26e890bdce, sha256 819b612977b8eeda9acb88917e9e86b9eb7cb83c5cfdf3e74d845493c12eb772)
BibTeX
@misc{dced26e890bdce,
  title = {PelviNeXt: A Modality-Agnostic Hybrid Network for Pelvic Imaging in Women's Health — arXiv:2608.20144},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.20144},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ed26e890bdce; sha256 819b612977b8eeda9acb88917e9e86b9eb7cb83c5cfdf3e74d845493c12eb772},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.20144. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Women's health remains substantially under-resourced in medical imaging research, with pelvic pathologies such as polycystic ovary syndrome (PCOS) and pelvic fracture both suffering from a scarcity of public, well-annotated benchmark data despite their clinical importance. We introduce PelviNeXt, a modality-agnostic hybrid architecture combining a dense convolutional feature extractor, hierarchical channel-spatial attention (H-CBAM), a multi-scale fusion module (MSFM), and talking-heads multi-head self-attention (TH-MHSA), applied without modification to both pelvic ultrasound and X-ray inputs. While benchmarking PelviNeXt on PCOSGen, the only gynaecologist-annotated public PCOS ultrasound dataset, we identified extensive exact and near-duplicate contamination within and across the dataset. We audit this contamination via perceptual hashing, publicly release a deduplicated version of the dataset, and establish the first integrity-audited evaluation protocol and baseline for PCOSGen under 5-fold cross-validation. On the only publicly available pelvic fracture X-ray dataset (PXR150), PelviNeXt exceeds previously reported state-of-the-art results across accuracy, recall, specificity, and AUROC. Ablation studies confirm that each architectural component contributes to performance on both tasks. Our results demonstrate that a single architecture, applied without task-specific modification, can serve as a reliable foundation for pelvic imaging across modalities in data-scarce, under-researched areas of women's health.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-21 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2608.20144 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-18T12:01:57.741Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-08-21?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).