Metraipolis › archive › dc_ecc8a87b9620

Error-Bounded Fixed-Point Design of Super-Sample-Rate IIR Filters for Real-Time Superconducting Qubit Flux Predistortion — arXiv:2609.16488

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.16488
License (as archived)
CC0-1.0
Archived
2026-10-15T22:05:32.165Z
SHA-256 of the archived text
de37bfc511f31e1e1692fa0294db49057006eadb04c8a5b9a20d70681e8ec06c
Stable URL of this page
https://metraipolis.com/documento/dc_ecc8a87b9620

How to cite

Error-Bounded Fixed-Point Design of Super-Sample-Rate IIR Filters for Real-Time Superconducting Qubit Flux Predistortion — arXiv:2609.16488 — arXiv (en), https://arxiv.org/abs/2609.16488 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ecc8a87b9620 (Metraipolis archive dc_ecc8a87b9620, sha256 de37bfc511f31e1e1692fa0294db49057006eadb04c8a5b9a20d70681e8ec06c)
BibTeX
@misc{dcecc8a87b9620,
  title = {Error-Bounded Fixed-Point Design of Super-Sample-Rate IIR Filters for Real-Time Superconducting Qubit Flux Predistortion — arXiv:2609.16488},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.16488},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ecc8a87b9620; sha256 de37bfc511f31e1e1692fa0294db49057006eadb04c8a5b9a20d70681e8ec06c},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.16488. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Flux-activated two-qubit gates in superconducting processors require correction of line distortion, which otherwise produces residual detuning, conditional-phase error, and leakage. Prior demonstrations of cryoscope-based distortion calibration have generally used commercial solutions that specify the filter models but not their FPGA implementation. These details matter for custom and open-source systems, where the fixed-point coefficient and datapath formats set how accurately the correction is realized, and the IIR feedback loop in its standard form does not meet timing at the required clock rate. We derive the coefficient formats of the correction filters from a step response error tolerance, using bounds on the quantization-induced displacement of the poles and zeros over the physical parameter range of each distortion, and the accumulator format from the smallest input change that must remain resolvable at the output. The same analysis gives the conditions under which quantization preserves filter stability. We implement the resulting FIR/IIR cascade on the QubiC platform at a fabric clock rate of \SI{500}{MHz}, using a super-sample-rate structure with scattered look-ahead pipelining, which removes the feedback recursion from the critical path without changing the target transfer function. A representative cascade for our \SI{1}{GS/s} flux lines, comprising an integrator, a second-order section, and a 20-tap FIR, consumes 88 DSP slices and adds \SI{162}{ns} of latency. We confirm the hardware implementation by correcting characteristic bias-tee distortion, an intermediate step toward full cryoscope-based calibration.

Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-16 in quant-ph).
Categorie arXiv: Quantum Physics (quant-ph).
Pagina del lavoro: https://arxiv.org/abs/2609.16488 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-15T21:52:12.794Z dalla pagina https://arxiv.org/catchup/quant-ph/2026-09-16?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).