Metraipolis › archive › dc_ec233c98cd6b
Does DCGAN-Based Synthetic Augmentation Improve Brain Tumor MRI Classification? An Empirical Study — arXiv:2609.28508
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.28508
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T06:44:46.911Z
- SHA-256 of the archived text
93fd851478e06fc90e63c07026d62e44ec7eddf6e4f2ae3f1cd3f226325b9c70- Stable URL of this page
https://metraipolis.com/documento/dc_ec233c98cd6b
How to cite
Does DCGAN-Based Synthetic Augmentation Improve Brain Tumor MRI Classification? An Empirical Study — arXiv:2609.28508 — arXiv (en), https://arxiv.org/abs/2609.28508 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ec233c98cd6b (Metraipolis archive dc_ec233c98cd6b, sha256 93fd851478e06fc90e63c07026d62e44ec7eddf6e4f2ae3f1cd3f226325b9c70)
BibTeX
@misc{dcec233c98cd6b,
title = {Does DCGAN-Based Synthetic Augmentation Improve Brain Tumor MRI Classification? An Empirical Study — arXiv:2609.28508},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.28508},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ec233c98cd6b; sha256 93fd851478e06fc90e63c07026d62e44ec7eddf6e4f2ae3f1cd3f226325b9c70},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.28508. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Generative adversarial networks (GANs) are increasingly used to augment medical imaging datasets, but synthetic images do not necessarily provide downstream classification benefits. This study investigates whether class-specific Deep Convolutional Generative Adversarial Network (DCGAN) augmentation improves brain tumor classification when the classifier and evaluation set are held constant. Experiments were conducted on 7,200 brain magnetic resonance imaging (MRI) scans across four classes: glioma, meningioma, pituitary tumor, and no tumor. For each class, 1,400 real images were used for training and 400 were reserved for testing. A baseline Swin Transformer classifier was trained using only the real training images and compared with a second model trained using the same real images augmented with 500 DCGAN-generated images per class. Both conditions were evaluated on the identical held-out test set. The two models achieved the same overall accuracy of 96%, while macro F1 remained effectively unchanged and ROC-AUC decreased slightly from 0.987 to 0.982 after augmentation. Class-level analysis showed small redistributions in errors rather than a consistent performance gain. FID values between real and synthetic images ranged from 209.15 to 314.27, indicating substantial distributional differences under the adopted evaluation setup. These results suggest that synthetic augmentation should not be assumed to improve medical image classification and should instead be evaluated for both distributional fidelity and downstream task utility. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-25 in cs.CV). Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.28508 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T06:09:29.920Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-25?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).