Metraipolis › archive › dc_eb3c037a69b6
Beyond Higher-Pulse Rectification: Operational Harmonic Coordination in Renewable P2H Systems — arXiv:2609.03531
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.03531
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T02:26:46.109Z
- SHA-256 of the archived text
f999fbbf3986cc26465270cc650bc311e7a51f1e2283f2b5b589bd424b14911d- Stable URL of this page
https://metraipolis.com/documento/dc_eb3c037a69b6
How to cite
Beyond Higher-Pulse Rectification: Operational Harmonic Coordination in Renewable P2H Systems — arXiv:2609.03531 — arXiv (en), https://arxiv.org/abs/2609.03531 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_eb3c037a69b6 (Metraipolis archive dc_eb3c037a69b6, sha256 f999fbbf3986cc26465270cc650bc311e7a51f1e2283f2b5b589bd424b14911d)
BibTeX
@misc{dceb3c037a69b6,
title = {Beyond Higher-Pulse Rectification: Operational Harmonic Coordination in Renewable P2H Systems — arXiv:2609.03531},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.03531},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_eb3c037a69b6; sha256 f999fbbf3986cc26465270cc650bc311e7a51f1e2283f2b5b589bd424b14911d},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.03531. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Thyristor rectifiers (TRs) are cost-effective electrolysis power supplies for renewable power-to-hydrogen (ReP2H) systems, but their harmonics may violate grid-code limits. In contrast to conventional solutions that rely on higher-pulse (such as 24-pulse) rectifiers, this paper proposes an operational harmonic coordination scheme that enables low-cost 12-pulse TRs to meet harmonic requirements through coordinated operation. First, a harmonic model quantifies the effects of rectifier transformer (RCT) tap positions and electrolytic currents, enabling harmonic cancellation among multiple electrolyzers (ELZs). A two-layer framework then coordinates hydrogen production and harmonic mitigation. Hourly scheduling determines ELZ commitment within the harmonic feasible region under renewable uncertainty using stochastic programming and a modified progressive hedging algorithm, while minute-level dispatch tracks renewable power and mitigates harmonics. A decomposition algorithm separates production dispatch from harmonic mitigation to improve computational efficiency. Case studies based on real-life projects show that the proposed method increases profit by 31% over current-only regulation. Annual simulations further show that coordinated 12-pulse TRs can replace 24-pulse rectifiers for harmonic compliance by exchanging additional RCT tap actions for lower transformer investment, reducing rectification-stage cost by 37.5%. Tema degli esploratori: matematica e informatica teorica (retro-catalogo arXiv: annunci del 2026-09-04 in math.OC). Categorie arXiv: Optimization and Control (math.OC) ; Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2609.03531 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-17T02:07:43.334Z dalla pagina https://arxiv.org/catchup/math.OC/2026-09-04?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).