Metraipolis › archive › dc_eb0ca674abd5
Scalable Small-Signal Stability Assessment of Power Systems Based on Frequency-Domain Quadratic Constraints — arXiv:2609.35424
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.35424
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T01:34:17.057Z
- SHA-256 of the archived text
3208bd66878af166f173059d0dedf919f659d20310bd1fb4a9362c738d828123- Stable URL of this page
https://metraipolis.com/documento/dc_eb0ca674abd5
How to cite
Scalable Small-Signal Stability Assessment of Power Systems Based on Frequency-Domain Quadratic Constraints — arXiv:2609.35424 — arXiv (en), https://arxiv.org/abs/2609.35424 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_eb0ca674abd5 (Metraipolis archive dc_eb0ca674abd5, sha256 3208bd66878af166f173059d0dedf919f659d20310bd1fb4a9362c738d828123)
BibTeX
@misc{dceb0ca674abd5,
title = {Scalable Small-Signal Stability Assessment of Power Systems Based on Frequency-Domain Quadratic Constraints — arXiv:2609.35424},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.35424},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_eb0ca674abd5; sha256 3208bd66878af166f173059d0dedf919f659d20310bd1fb4a9362c738d828123},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.35424. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Small-signal stability analysis of power electronics-dominated power systems is becoming increasingly challenging due to the large-scale integration of heterogeneous grid-following (GFL) and grid-forming (GFM) converters. Classical centralized methods, such as eigenvalue analysis and the generalized Nyquist criterion, provide direct stability assessment tools but exhibit limited scalability as the system size increases. This motivates scalable analysis methods for stability assessment and device-level diagnosis, and calls for less conservative stability conditions. To this end, this paper proposes a scalable small-signal stability assessment method with quantitative stability indices for multi-converter systems based on frequency-domain quadratic constraints (FQCs). It is shown that several existing stability conditions, including geometric conditions based on the Davis-Wielandt (DW) shell, numerical range, $x$-$z$ graph, scaled relative graph (SRG), mixed gain-phase condition, and passivity condition, are special cases of the FQC-based stability condition. This FQC-based formulation also clarifies the requirements for decentralized verification of these existing stability conditions. To further reduce conservatism, a full-multiplier FQC-based stability condition is developed, based on which an optimization problem is formulated for scalable stability certification and device-level diagnosis using quantitative stability indices without relying on graphical inspection. Combined with the mixed gain-phase condition, this optimization problem forms a hierarchical screening-diagnosis procedure that improves efficiency. Case studies demonstrate that the proposed method is less conservative than existing criteria and can effectively identify problematic devices associated with potential instability risks. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-29 in eess.SY). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2609.35424 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T01:10:47.845Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).