Metraipolis › archive › dc_ea50b49678c6
XFlow: A Workflow Model for Instruction-Guided Lesion Segmentation in Chest X-rays — arXiv:2609.34513
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.34513
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-07T23:52:12.726Z
- SHA-256 of the archived text
c13406d833ee6c75157d95004be759dec63dbf35c0aee3c4188b7ffda72e3e33- Stable URL of this page
https://metraipolis.com/documento/dc_ea50b49678c6
How to cite
XFlow: A Workflow Model for Instruction-Guided Lesion Segmentation in Chest X-rays — arXiv:2609.34513 — arXiv (en), https://arxiv.org/abs/2609.34513 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ea50b49678c6 (Metraipolis archive dc_ea50b49678c6, sha256 c13406d833ee6c75157d95004be759dec63dbf35c0aee3c4188b7ffda72e3e33)
BibTeX
@misc{dcea50b49678c6,
title = {XFlow: A Workflow Model for Instruction-Guided Lesion Segmentation in Chest X-rays — arXiv:2609.34513},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.34513},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ea50b49678c6; sha256 c13406d833ee6c75157d95004be759dec63dbf35c0aee3c4188b7ffda72e3e33},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.34513. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Existing text-guided segmentation models in the medical domain cover only a narrow set of anatomical structures and lesions in chest X-rays (CXRs), and most of them assume that the queried target is always present in the image. Instruction-guided lesion segmentation (ILS) was introduced to overcome these limitations by segmenting diverse lesion types from simple user instructions while also recognizing when the queried lesion is absent, and ROSALIA was proposed as the first model for this task. However, the masks produced by ROSALIA remain of limited quality, often carrying scattered noise. Moreover, ROSALIA predicts the mask in a single shot, which differs fundamentally from how radiologists perceive and delineate lesions in practice. A radiologist first surveys the entire thorax, then localizes the approximate region of abnormality, and only then refines the lesion contour. Motivated by this coarse-to-fine, multi-level perception process, we present XFlow, a workflow model for ILS that combines box-based localization with multi-turn point refinement. XFlow detects the lungs, decides whether the queried finding is present in each of them, and prompts a fine-tuned SAM with the lesion box for an initial mask. It then corrects that mask through point prompts until its boundary follows the lesion, leaving every intermediate decision visible. Our experiments show that XFlow achieves the best segmentation quality on both internal and external evaluation. Notably, it surpasses ROSALIA in segmentation quality even when the two are trained on the same lesion annotations. Code and model weights will be made publicly available. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-29 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.34513 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-07T23:29:27.384Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).