Metraipolis › archive › dc_ea00120bdbaa
Characterisation of the ILMT 4K x 4K TDI CCD imager — arXiv:2610.38362
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.38362
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-01T02:55:06.092Z
- SHA-256 of the archived text
0db914ee114964779a46c523968e74b8c9d23aa5f7a9c083a54ff6ad3d76939b- Stable URL of this page
https://metraipolis.com/documento/dc_ea00120bdbaa
How to cite
Characterisation of the ILMT 4K x 4K TDI CCD imager — arXiv:2610.38362 — arXiv (en), https://arxiv.org/abs/2610.38362 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_ea00120bdbaa (Metraipolis archive dc_ea00120bdbaa, sha256 0db914ee114964779a46c523968e74b8c9d23aa5f7a9c083a54ff6ad3d76939b)
BibTeX
@misc{dcea00120bdbaa,
title = {Characterisation of the ILMT 4K x 4K TDI CCD imager — arXiv:2610.38362},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.38362},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_ea00120bdbaa; sha256 0db914ee114964779a46c523968e74b8c9d23aa5f7a9c083a54ff6ad3d76939b},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.38362. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
In this work, we determine the gain and read-out noise of the 4Kx4K CCD imager used with the 4-m International Liquid Mirror Telescope (ILMT). Due to the zenith-pointing characteristic of the telescope, the CCD operates in the Time Delay Integration (TDI) mode for image acquisition. The CCD frames obtained during rising twilight have non-uniform illumination and can potentially be used to calculate important CCD parameters using two approaches. The first approach directly measures variance in flux along rows with minimum horizontal gradient, despite the strong vertical illumination gradient. The second method divides the CCD frame into regions exposed to similar background illumination and analyses the flux ratio variation between the two regions. Mathematically, we establish a linear relationship between the signal variance and average flux, from which gain is determined, while the read-out noise (RON) is measured independently from the bias frames. Both methods provide a gain value of approximately 3.9 e/ADU, while the RON measured from bias frames is 1.55 ADU (~ 6 e). Estimation of these parameters provides a better understanding of the CCD performance and allows for an accurate calibration. Tema degli esploratori: fisica e astronomia (elenco arXiv astro-ph.IM, nuovi lavori del giorno). Categorie arXiv: Instrumentation and Methods for Astrophysics (astro-ph.IM). Pagina del lavoro: https://arxiv.org/abs/2610.38362 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-01T02:22:13.248Z dalla pagina https://arxiv.org/list/astro-ph.IM/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).