Metraipolis › archive › dc_e9292dab65d7

Evaluating Deep Multivariate Imputation Models on Wearable Device Data — arXiv:2608.24436

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.24436
License (as archived)
CC0-1.0
Archived
2026-10-18T06:36:14.177Z
SHA-256 of the archived text
ea8d4cff8121a55c5fe7270e4bd991aee30f79dfce00fe705185c0df4000f525
Stable URL of this page
https://metraipolis.com/documento/dc_e9292dab65d7

How to cite

Evaluating Deep Multivariate Imputation Models on Wearable Device Data — arXiv:2608.24436 — arXiv (en), https://arxiv.org/abs/2608.24436 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_e9292dab65d7 (Metraipolis archive dc_e9292dab65d7, sha256 ea8d4cff8121a55c5fe7270e4bd991aee30f79dfce00fe705185c0df4000f525)
BibTeX
@misc{dce9292dab65d7,
  title = {Evaluating Deep Multivariate Imputation Models on Wearable Device Data — arXiv:2608.24436},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.24436},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_e9292dab65d7; sha256 ea8d4cff8121a55c5fe7270e4bd991aee30f79dfce00fe705185c0df4000f525},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.24436. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Wearable device data enables continuous health monitoring, but suffers from structured missingness: features sharing a physical sensor drop out together. Deep imputation methods such as BRITS and SAITS have seen limited evaluation on multimodal physiological data under realistic missingness, and existing benchmarks use random-point holdout protocols that incorrectly assume missingness is independent across features and time. Using data from a person with epilepsy recorded on a Garmin smartwatch, we develop an evaluation protocol that mines contiguous missing-run templates from training data, stratifies them by per-feature gap-length quantiles, and injects them as block masks with preserved co-missingness structure. A matched training protocol exposing models to the same missingness distribution reduces BRITS's severe-gap MAE by 43%, demonstrating the potential benefit of the proposed evaluation and training protocol within this single-participant dataset. We further extend BRITS with time-of-day encoding and a circadian harmonic channel. No single model dominates: linear interpolation is optimal for slow-moving features over short gaps; extended BRITS achieves lower MAE on dynamic cardiac features in moderate and severe gaps; and SAITS better preserves the ground-truth distribution by Jensen-Shannon distance despite higher MAE. Ultimately, model rankings strongly depend on evaluation designs. By exposing how traditional evaluation methods obscure true model capabilities, our transferable protocol establishes critical steps towards developing better imputation strategies for future multi-sensor wearable datasets.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-26 in cs.LG).
Categorie arXiv: Machine Learning (cs.LG) ; Artificial Intelligence (cs.AI); Quantitative Methods (q-bio.QM).
Pagina del lavoro: https://arxiv.org/abs/2608.24436 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-18T06:28:52.248Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-08-26?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).