Metraipolis › archive › dc_e8478709ba10

Manifold-Constrained PET Reconstruction with Learned Flow-Matching Priors — arXiv:2608.29158

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.29158
License (as archived)
CC0-1.0
Archived
2026-10-17T10:43:05.825Z
SHA-256 of the archived text
608818613e3cd77f1c63e21bdc32f289c8776321f76d5f320e6b8b132dbb0164
Stable URL of this page
https://metraipolis.com/documento/dc_e8478709ba10

How to cite

Manifold-Constrained PET Reconstruction with Learned Flow-Matching Priors — arXiv:2608.29158 — arXiv (en), https://arxiv.org/abs/2608.29158 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_e8478709ba10 (Metraipolis archive dc_e8478709ba10, sha256 608818613e3cd77f1c63e21bdc32f289c8776321f76d5f320e6b8b132dbb0164)
BibTeX
@misc{dce8478709ba10,
  title = {Manifold-Constrained PET Reconstruction with Learned Flow-Matching Priors — arXiv:2608.29158},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.29158},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_e8478709ba10; sha256 608818613e3cd77f1c63e21bdc32f289c8776321f76d5f320e6b8b132dbb0164},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.29158. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Image reconstruction for positron emission tomography (PET) is an ill-posed Poisson inverse problem that often suffers from severe noise amplification and artifacts. In this work, we introduce an unsupervised, optimization-based reconstruction framework that employs a flow-matching generative model as a learned manifold prior. We train the flow-matching model on high-quality PET images to learn a deterministic ordinary differential equation transport from a Gaussian latent distribution to the empirical PET image distribution, yielding a differentiable generator of anatomically plausible images. We incorporate this generator as an explicit manifold constraint into a regularized Poisson likelihood formulation. We solve the resulting optimization problem using an alternating direction method of multipliers algorithm, in which an expectation-maximization-type surrogate update enforces data consistency and a gradient-based latent-space projection enforces manifold proximity. We evaluate the proposed method on both simulated and real PET datasets, assessing dose-level robustness, lesion-insertion generalization, and cross-scanner transfer. Compared with conventional reconstruction methods and state-of-the-art deep learning baselines, the proposed method provides superior noise suppression, structural preservation, and quantitative accuracy, while maintaining high computational efficiency.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-01 in eess.IV).
Categorie arXiv: Image and Video Processing (eess.IV).
Pagina del lavoro: https://arxiv.org/abs/2608.29158 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T10:33:05.794Z dalla pagina https://arxiv.org/catchup/eess.IV/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).