Metraipolis › archive › dc_e75ee4017301
When Gigawatts of Computational Load Disappear: Cycle-Space Certificates for Grid Synchronization and Transient Stability — arXiv:2609.27989
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.27989
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T13:08:42.493Z
- SHA-256 of the archived text
bf544bdc68e58e4c571e24771b916a0cc01e172486c48e0e9c9ccdcff36fb2a9- Stable URL of this page
https://metraipolis.com/documento/dc_e75ee4017301
How to cite
When Gigawatts of Computational Load Disappear: Cycle-Space Certificates for Grid Synchronization and Transient Stability — arXiv:2609.27989 — arXiv (en), https://arxiv.org/abs/2609.27989 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_e75ee4017301 (Metraipolis archive dc_e75ee4017301, sha256 bf544bdc68e58e4c571e24771b916a0cc01e172486c48e0e9c9ccdcff36fb2a9)
BibTeX
@misc{dce75ee4017301,
title = {When Gigawatts of Computational Load Disappear: Cycle-Space Certificates for Grid Synchronization and Transient Stability — arXiv:2609.27989},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.27989},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_e75ee4017301; sha256 bf544bdc68e58e4c571e24771b916a0cc01e172486c48e0e9c9ccdcff36fb2a9},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.27989. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Rapid growth of data centers and artificial-intelligence services is producing computational loads at scales once associated mainly with largest power plants. Recent grid events show that a routine transmission disturbance can cause several gigawatts of data-center demand to disconnect or transfer to backup nearly at once. This article revisits the classical synchronization and transient-stability theory needed to reason about such events. We organize four lines of work---graph-based synchronization conditions, winding-number descriptions of nonlinear power flow, separable convex network optimization, and direct energy methods---into a single cycle-space certificate framework for the lossless fixed-voltage model. The static layer gives an exact strict-cohesion test within a prescribed winding cell and reveals the widely used Dörfler--Chertkov--Bullo test as a quadratic surrogate of the same convex problem. The dynamic layer converts the critical-energy calculation into a finite family of convex boundary problems. Standard MATPOWER benchmarks illustrate both what the stronger static test gains and where it gains nothing: the 118-bus case admits $16.2\%$ more loading than the sufficient screen, while the 39-bus case is bridge-limited and the thresholds coincide. A stylized $2.7$-GW 39-bus event further shows that transient margin can change by about a factor of two depending on where balancing power is supplied, even when every final balanced operating point remains statically feasible. The result is a tutorial synthesis and an extensible deterministic certificate for emerging gigawatt-scale computational-load contingencies. Tema degli esploratori: governance digitale e beni comuni (retro-catalogo arXiv: annunci del 2026-09-24 in physics.soc-ph). Categorie arXiv: Systems and Control (eess.SY) ; Dynamical Systems (math.DS); Physics and Society (physics.soc-ph). Pagina del lavoro: https://arxiv.org/abs/2609.27989 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T13:07:01.543Z dalla pagina https://arxiv.org/catchup/physics.soc-ph/2026-09-24?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).