Metraipolis › archive › dc_e707d2ea6b53
Enhanced thermal effect using magnetic nano-particles during high-intensity focused ultrasound — Europe PMC PMID:28384646
- Source
- Europe PMC (en)
- Original
- https://europepmc.org/article/MED/28384646
- DOI
- 10.1371/journal.pone.0175093
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T11:33:46.056Z
- SHA-256 of the archived text
aff9b1ffd0bea498baec36831b861627f0e560229b3b40aa61abcdd8b3f36509- Stable URL of this page
https://metraipolis.com/documento/dc_e707d2ea6b53
How to cite
Enhanced thermal effect using magnetic nano-particles during high-intensity focused ultrasound — Europe PMC PMID:28384646 — Europe PMC (en), https://europepmc.org/article/MED/28384646 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_e707d2ea6b53 (Metraipolis archive dc_e707d2ea6b53, sha256 aff9b1ffd0bea498baec36831b861627f0e560229b3b40aa61abcdd8b3f36509)
BibTeX
@misc{dce707d2ea6b53,
title = {Enhanced thermal effect using magnetic nano-particles during high-intensity focused ultrasound — Europe PMC PMID:28384646},
howpublished = {Europe PMC (en)},
url = {https://europepmc.org/article/MED/28384646},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_e707d2ea6b53; sha256 aff9b1ffd0bea498baec36831b861627f0e560229b3b40aa61abcdd8b3f36509},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/28384646. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Collateral damage and long sonication times occurring during high-intensity focused ultrasound (HIFU) ablation procedures limit clinical advancement. In this reserarch, we investigated whether the use of magnetic nano-particles (mNPs) can reduce the power required to ablate tissue or, for the same power, reduce the duration of the procedure. Tissue-mimicking phantoms containing embedded thermocouples and physiologically acceptable concentrations (0%, 0.0047%, and 0.047%) of mNPs were sonicated at acoustic powers of 5.2 W, 9.2 W, and 14.5 W, for 30 seconds. Lesion volumes were determined for the phantoms with and without mNPs. It was found that with the 0.047% mNP concentration, the power required to obtain a lesion volume of 13 mm3 can be halved, and the time required to achieve a 21 mm3 lesion decreased by a factor of 5. We conclude that mNPs have the potential to reduce damage to healthy tissue, and reduce the procedure time, during tumor ablation using HIFU. Tema degli esploratori: fisica e astronomia (ricerca Europe PMC «particle physics», solo open access). Pubblicazione: PloS one, 2017 (prima pubblicazione 2017-04-06). Identificativi: PMID 28384646 · PMCID PMC5383424 · DOI 10.1371/journal.pone.0175093. Descrittori MeSH principali: Magnetics; Nanoparticles. Pagina: https://europepmc.org/article/MED/28384646 — https://doi.org/10.1371/journal.pone.0175093. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0. Letto il 2026-10-08T10:31:57.948Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.