Metraipolis › archive › dc_e6f1bbc9a235

Harnessing Magnitude-Only and Complex Measurements for Improved Dynamic MRI Reconstruction with Learned Priors — arXiv:2608.18036

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.18036
License (as archived)
CC0-1.0
Archived
2026-10-18T14:33:51.523Z
SHA-256 of the archived text
759b720732df6e0a4fdf82a33d1b75450887bbaea831ad5474742275030d383e
Stable URL of this page
https://metraipolis.com/documento/dc_e6f1bbc9a235

How to cite

Harnessing Magnitude-Only and Complex Measurements for Improved Dynamic MRI Reconstruction with Learned Priors — arXiv:2608.18036 — arXiv (en), https://arxiv.org/abs/2608.18036 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_e6f1bbc9a235 (Metraipolis archive dc_e6f1bbc9a235, sha256 759b720732df6e0a4fdf82a33d1b75450887bbaea831ad5474742275030d383e)
BibTeX
@misc{dce6f1bbc9a235,
  title = {Harnessing Magnitude-Only and Complex Measurements for Improved Dynamic MRI Reconstruction with Learned Priors — arXiv:2608.18036},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.18036},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_e6f1bbc9a235; sha256 759b720732df6e0a4fdf82a33d1b75450887bbaea831ad5474742275030d383e},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.18036. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

MRI reconstruction methods for undersampled k-space data naturally utilize complex-valued measurements. Parallel developments in sparse phase retrieval have shown that magnitude-only measurements may provide complementary information for signal recovery. However, their use in MRI reconstruction remains largely unexplored, due to lack of practical settings where informative magnitude measurements can be obtained without additional scan time. In this work, we investigate the use of auxiliary k-space magnitude information for accelerated steady-state dynamic MRI reconstruction, and demonstrate strong consistency of k-space magnitudes across time-frames. Building on this observation, we propose $\mathbb{C}+\text{Mag}$, a magnitude-informed physics-driven deep learning reconstruction method. The proposed method employs an ADMM-based unrolling framework with a novel magnitude-aware data-fidelity formulation, where quadratically smoothed optimization and momentum-based updates are introduced to address the non-differentiability and non-convexity of the magnitude constraints. Experiments on retrospectively undersampled cine MRI and phase-contrast flow MRI datasets, as well as prospectively undersampled real-time cine MRI acquisitions, demonstrate improved artifact suppression, sharper anatomical recovery, and better preservation of phase information compared to conventional PD-DL methods, which is further supported through blinded expert reader evaluations.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-19 in cs.AI).
Categorie arXiv: Image and Video Processing (eess.IV) ; Artificial Intelligence (cs.AI); Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG); Medical Physics (physics.med-ph).
Pagina del lavoro: https://arxiv.org/abs/2608.18036 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-18T14:27:54.481Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-08-19?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).