Metraipolis › archive › dc_e5ca2828c61e
Automatic Reproducible Camera Intrinsic Calibration — arXiv:2609.10082
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.10082
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T11:00:14.143Z
- SHA-256 of the archived text
0edd5faea6ab867044e0faf7989e8025830f10371a53faf34223eb47695cad91- Stable URL of this page
https://metraipolis.com/documento/dc_e5ca2828c61e
How to cite
Automatic Reproducible Camera Intrinsic Calibration — arXiv:2609.10082 — arXiv (en), https://arxiv.org/abs/2609.10082 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_e5ca2828c61e (Metraipolis archive dc_e5ca2828c61e, sha256 0edd5faea6ab867044e0faf7989e8025830f10371a53faf34223eb47695cad91)
BibTeX
@misc{dce5ca2828c61e,
title = {Automatic Reproducible Camera Intrinsic Calibration — arXiv:2609.10082},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.10082},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_e5ca2828c61e; sha256 0edd5faea6ab867044e0faf7989e8025830f10371a53faf34223eb47695cad91},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.10082. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Accurate camera intrinsic calibration is fundamental to robot perception, and the accuracy depends on the quality of the collected images. However, existing target-based calibration methods often require the practitioner to manually filter out high-quality images and to specify an appropriate radial distortion order. This paper presents a fully automatic intrinsic calibration pipeline that determines both from the collected data. We adopt an iterative rejection scheme that estimates parameters on a candidate image set and removes views whose mean residual exceeds a multiple of the median. Crucially, this process runs independently under each candidate distortion order, so that the retained image set is consistent with the residual scale of that order. Further, the distortion order is selected on held-out images, with the intrinsics and distortion fixed and only the board pose re-estimated, ensuring that an added coefficient is supported by independent observations. Finally, we integrate both steps into an interactive calibration tool that supports full-pipeline data inspection and parameter estimation. Experiments on our own camera data and five public real-world datasets show that image filtering reduces the held-out reprojection error by 25\%, the order selection further by 5\%, achieving the lowest held-out mean among four compared configurations without manual image selection. We will release the code and data to facilitate future research. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-10 in cs.CV). Categorie arXiv: Robotics (cs.RO) ; Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.10082 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T10:02:34.435Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-10?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).