Metraipolis › archive › dc_e35e963d0eb8
Self-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits — arXiv:2609.11650
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.11650
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T06:35:45.433Z
- SHA-256 of the archived text
cc342234568fac6d11bace73d65062e975112c03012e51ee3479a8a96539f707- Stable URL of this page
https://metraipolis.com/documento/dc_e35e963d0eb8
How to cite
Self-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits — arXiv:2609.11650 — arXiv (en), https://arxiv.org/abs/2609.11650 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_e35e963d0eb8 (Metraipolis archive dc_e35e963d0eb8, sha256 cc342234568fac6d11bace73d65062e975112c03012e51ee3479a8a96539f707)
BibTeX
@misc{dce35e963d0eb8,
title = {Self-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits — arXiv:2609.11650},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.11650},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_e35e963d0eb8; sha256 cc342234568fac6d11bace73d65062e975112c03012e51ee3479a8a96539f707},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.11650. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Accurate identification of end-diastole (ED) and end-systole (ES) in echocardiography underpins the quantification of ventricular function, yet manual selection of these key frames is subjective and introduces clinically significant inter-operator variability. Recent self-supervised methods either prescribe strict periodic trajectories or learn an unconstrained low-dimensional motion subspace from reconstruction or registration objectives. The former offers interpretability but imposes restrictive assumptions on temporal progression, whereas the latter leaves cardiac phase implicit and ED/ES must be recovered through post-hoc geometric processing of the learned trajectory. We translate the physiological observation that cardiac phase is a one-dimensional signal into a prior by constraining the latent motion component to a single-parameter latent orbit, i.e., a global linear trajectory in latent space indexed by a bounded scalar phase variable. Mapping this variable through a sinusoidal nonlinearity yields an oscillatory motion signal with consistent temporal ordering, enabling direct identification of ED and ES from the learned phase signal. This inductive bias allows the model to capture an interpretable representation of the cardiac cycle, while maintaining flexibility to capture irregular heartbeats. Trained on EchoNet-Dynamic without annotations, our minimal single-parameter cardiac phase model learns an effective latent orbit, significantly improves upon the previous state of the art in ED localisation and matches it in ES localisation while using a more constrained representation and fewer training epochs. This demonstrates that a principled physiological inductive bias can match or exceed the performance of more complex representations. Code is available at: this https URL Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-11 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.11650 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T06:06:28.799Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-11?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).