Metraipolis › archive › dc_e343e72c8771
Uncertainty calibration in Bayesian M/EEG source imaging — arXiv:2611.06979
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.06979
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-06T14:44:02.660Z
- SHA-256 of the archived text
ae5feac22fa4dcf47f7b9d078b5e7d2a666d5f280420866e7cf1a6b176ceebbb- Stable URL of this page
https://metraipolis.com/documento/dc_e343e72c8771
How to cite
Uncertainty calibration in Bayesian M/EEG source imaging — arXiv:2611.06979 — arXiv (en), https://arxiv.org/abs/2611.06979 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_e343e72c8771 (Metraipolis archive dc_e343e72c8771, sha256 ae5feac22fa4dcf47f7b9d078b5e7d2a666d5f280420866e7cf1a6b176ceebbb)
BibTeX
@misc{dce343e72c8771,
title = {Uncertainty calibration in Bayesian M/EEG source imaging — arXiv:2611.06979},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.06979},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_e343e72c8771; sha256 ae5feac22fa4dcf47f7b9d078b5e7d2a666d5f280420866e7cf1a6b176ceebbb},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.06979. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
M/EEG source imaging requires accurate localization and reliable uncertainty estimates, yet posterior credible regions are rarely assessed for empirical calibration. We present a simulation-based framework for uncertainty quantification and calibration of empirical Bayesian inverse methods with closed-form conditional Gaussian posterior summaries. We compare Bayesian minimum norm (BMN) with sLORETA depth weighting and sparse Bayesian learning (SBL) with sparse basis field expansions (S-FLEX). S-FLEX allows retained coefficients to contribute nonzero marginal posterior variance at locations where voxel-wise SBL yields degenerate variances. For BMN, we derive joint source- and noise-variance updates through evidence maximization. We test whether adaptive noise learning yields near-calibrated uncertainties. Both methods retain residual miscalibration, motivating post-hoc isotonic recalibration of credible-region levels using empirical coverage. Simulations assess fixed- and free-orientation models across signal-to-noise ratios (SNR), source sparsity levels, and subject-specific head models, using oracle, baseline-estimated, and adaptively learned noise. Before recalibration, SBL+S-FLEX yields lower Wasserstein localization error, smaller posterior uncertainty, and coverage closer to nominal credibility than BMN+sLORETA. Isotonic recalibration improves both methods, with larger gains for conservative BMN+sLORETA posteriors; transfer across mismatched SNR, sparsity, and head models remains condition dependent. Noise specifications yield broadly consistent reconstruction and uncertainty trends within each estimator. In real auditory MEG data, SBL+S-FLEX provides more focal localization and tighter uncertainties than BMN+sLORETA, suggesting greater statistical power for identifying bilateral auditory sources. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.LG, nuovi lavori del giorno). Categorie arXiv: Machine Learning (cs.LG) ; Computational Engineering, Finance, and Science (cs.CE). Pagina del lavoro: https://arxiv.org/abs/2611.06979 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-06T14:21:42.610Z dalla pagina https://arxiv.org/list/cs.LG/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).