Metraipolis › archive › dc_e332354239fd

Sub-shot-noise mid-infrared photothermal measurements using twin beams — arXiv:2610.10294

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.10294
License (as archived)
CC0-1.0
Archived
2026-10-08T14:05:03.958Z
SHA-256 of the archived text
7662c3456db94ba8598dfa9eafdc30d04faa7da41cef99e38a32357dff2b3a4a
Stable URL of this page
https://metraipolis.com/documento/dc_e332354239fd

How to cite

Sub-shot-noise mid-infrared photothermal measurements using twin beams — arXiv:2610.10294 — arXiv (en), https://arxiv.org/abs/2610.10294 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_e332354239fd (Metraipolis archive dc_e332354239fd, sha256 7662c3456db94ba8598dfa9eafdc30d04faa7da41cef99e38a32357dff2b3a4a)
BibTeX
@misc{dce332354239fd,
  title = {Sub-shot-noise mid-infrared photothermal measurements using twin beams — arXiv:2610.10294},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.10294},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_e332354239fd; sha256 7662c3456db94ba8598dfa9eafdc30d04faa7da41cef99e38a32357dff2b3a4a},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.10294. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Mid-infrared photothermal (MIP) measurement probes refractive-index changes induced by mid-infrared (MIR) absorption using visible or near-infrared light and has recently emerged as a powerful modality for MIR spectro-imaging in the life sciences. Reducing measurement noise allows the probe power to be lowered without compromising the signal-to-noise ratio (SNR), thereby mitigating the risk of sample damage. However, even in the absence of classical noise, the SNR of conventional MIP measurements using a classical coherent probe is fundamentally limited by shot noise. Here, we demonstrate sub-shot-noise MIP measurement using twin beams generated through seeded optical parametric amplification. Balanced detection of the twin beams suppresses the noise by more than 5 dB below the shot-noise level established using a coherent beam. As a proof-of-principle demonstration, we measure the MIP signal from liquid water using balanced twin-beam detection and achieve an SNR enhancement of more than 2 dB over the balanced coherent-beam detection.

Tema degli esploratori: fisica e astronomia (elenco arXiv quant-ph, nuovi lavori del giorno).
Categorie arXiv: Optics (physics.optics) ; Quantum Physics (quant-ph).