Metraipolis › archive › dc_e14820d912d8

Shaft-Configuration-Adaptive Catheter Tip Position Estimation via Motor-History Conditioned Residual Learning — arXiv:2609.26304

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.26304
License (as archived)
CC0-1.0
Archived
2026-10-08T16:43:53.766Z
SHA-256 of the archived text
030570c6e2f43ee789562ddf620404e53412c21b7ac00440891584b6b6105974
Stable URL of this page
https://metraipolis.com/documento/dc_e14820d912d8

How to cite

Shaft-Configuration-Adaptive Catheter Tip Position Estimation via Motor-History Conditioned Residual Learning — arXiv:2609.26304 — arXiv (en), https://arxiv.org/abs/2609.26304 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_e14820d912d8 (Metraipolis archive dc_e14820d912d8, sha256 030570c6e2f43ee789562ddf620404e53412c21b7ac00440891584b6b6105974)
BibTeX
@misc{dce14820d912d8,
  title = {Shaft-Configuration-Adaptive Catheter Tip Position Estimation via Motor-History Conditioned Residual Learning — arXiv:2609.26304},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.26304},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_e14820d912d8; sha256 030570c6e2f43ee789562ddf620404e53412c21b7ac00440891584b6b6105974},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.26304. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Tendon-driven continuum manipulators are widely used in medical applications, where accurate tip-position estimation is essential for precise navigation and instrument positioning. However, patient anatomy and procedural setup impose task-dependent unknown shaft configurations, while friction, slack, and compliance introduce hysteresis, making tip estimation challenging. This paper presents a motor-history-conditioned gated recurrent unit (GRU) residual estimator for three-dimensional catheter tip estimation without direct shaft-configuration sensing. First, an initial multidirectional sweep strategy is applied to calibrate a geometric catheter model backbone, and encode the motor-angle and drive-torque response into a shaft-configuration context vector. During subsequent motion, the context conditions a GRU that predicts a task-space residual correcting this backbone, relying on motor measurements alone. The context remains fixed for the current shaft configuration, while the recurrent state captures the evolving actuation history. Across four disposable intra-cardiac echocardiography catheters and 16 bent shaft configurations, the method achieves 3.3mm open-loop tip RMSE, a 59% reduction relative to the constant-curvature baseline.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-23 in cs.RO).
Categorie arXiv: Robotics (cs.RO) ; Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2609.26304 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T15:56:53.493Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-09-23?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).