Integrating Data Center Flexibility into Power System Operations: A Framework for Temporal Redispatch — arXiv:2611.02228
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.02228
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-03T11:32:24.698Z
- SHA-256 of the archived text
efa39aa556e67cb0b27184bd2a8627c3ad3fd26f509fca87d03ee758c8431afe- Stable URL of this page
https://metraipolis.com/documento/dc_df8e7e4d04da
How to cite
Integrating Data Center Flexibility into Power System Operations: A Framework for Temporal Redispatch — arXiv:2611.02228 — arXiv (en), https://arxiv.org/abs/2611.02228 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_df8e7e4d04da (Metraipolis archive dc_df8e7e4d04da, sha256 efa39aa556e67cb0b27184bd2a8627c3ad3fd26f509fca87d03ee758c8431afe)
BibTeX
@misc{dcdf8e7e4d04da,
title = {Integrating Data Center Flexibility into Power System Operations: A Framework for Temporal Redispatch — arXiv:2611.02228},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.02228},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_df8e7e4d04da; sha256 efa39aa556e67cb0b27184bd2a8627c3ad3fd26f509fca87d03ee758c8431afe},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.02228. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Rapid growth in data center electricity demand, driven by artificial intelligence (AI) training and inference, is expected to increase stress conditions for power grids. Operational flexibility from data centers offers a near-term lever to relieve such stresses. Existing models of data center flexibility tend to bundle economic incentives with physical constraints, obscuring the tradeoff between economic willingness to shift load and technical limitations to do so. This paper proposes a temporal-redispatch focused framework that decouples data center demand flexibility into two independently parameterized dimensions: (1) systematic flexibility, capturing the economic environment through penalties for temporal shifting of data centers' scheduled demand, and (2) operational flexibility, capturing the physical envelope through the demand shifting time window and the limit on shifted data center demand. The framework relies on a direct current optimal power flow (DC-OPF) linear program which enables annual parametric analysis at hourly resolution. The framework is studied using a synthetic grid mimicking the Texas transmission system populated with the 2026 Adjusted Forecast from ERCOT (Electric Reliability Council of Texas). Results show that operational flexibility imposes a physical lower bound on unsatisfied demand that no economic incentive can overcome; longer shifting windows and higher limits on shifted data center demand reduce operational cost with different impacts on grid utilization; and, temporal redispatch shaves system-wide net load peaks while partially compensating for localized transmission bottlenecks that emerge under modeled coal retirement scenarios. Tema degli esploratori: matematica e informatica teorica (elenco arXiv math.OC, nuovi lavori del giorno). Categorie arXiv: Optimization and Control (math.OC). Pagina del lavoro: https://arxiv.org/abs/2611.02228 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-03T11:04:22.258Z dalla pagina https://arxiv.org/list/math.OC/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).