Metraipolis › archive › dc_de343e5dd391

RadFusion: Towards Threshold-Controllable Radiology Report Generation — arXiv:2608.10505

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.10505
License (as archived)
CC0-1.0
Archived
2026-10-19T06:08:27.713Z
SHA-256 of the archived text
e7b1851eeaf345105affe74eafa73953890d964ee665a8e11dd40eb5293e08d1
Stable URL of this page
https://metraipolis.com/documento/dc_de343e5dd391

How to cite

RadFusion: Towards Threshold-Controllable Radiology Report Generation — arXiv:2608.10505 — arXiv (en), https://arxiv.org/abs/2608.10505 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_de343e5dd391 (Metraipolis archive dc_de343e5dd391, sha256 e7b1851eeaf345105affe74eafa73953890d964ee665a8e11dd40eb5293e08d1)
BibTeX
@misc{dcde343e5dd391,
  title = {RadFusion: Towards Threshold-Controllable Radiology Report Generation — arXiv:2608.10505},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.10505},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_de343e5dd391; sha256 e7b1851eeaf345105affe74eafa73953890d964ee665a8e11dd40eb5293e08d1},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.10505. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Automated radiology report generation is advancing rapidly in response to the shortage of radiologists, yet unlike a perception model, existing generation models offer no control over the sensitivity-specificity trade-off of their diagnostic content. Such control is essential because clinical scenarios diverge: emergency triage prioritizes sensitivity to reduce missed findings, whereas confirmatory interpretation emphasizes specificity to limit unnecessary interventions. A single fixed report can neither adapt to these scenarios nor support the ROC-based validation widely expected for regulatory clearance. We introduce RadFusion, a framework that equips report generation with threshold controllability. Our method fuses a multi-label classifier, which provides per-disease confidence scores, with a VQA-based report generator, which describes medical findings in detail; an LLM then rewrites the report so that its stated diagnoses follow the classifier's decisions at the selected threshold while staying grounded in the generator's descriptions. On MIMIC-CXR, the performance of RadFusion conforms to the classifier's ROC curve: sweeping the threshold and mapping the reports back to class labels reproduces the classifier's validated ROC performance. This conformance makes generated reports quantitatively evaluable through ROC analysis, strengthening the case for regulatory clearance, and enables operating-point selection that matches report behavior to clinical context. Moreover, combining the two model types improves diagnostic accuracy over uncontrolled generation: sensitivity increases by 6.9% at matched specificity, and specificity by 20.7% at matched sensitivity. These results show that RadFusion makes report generation clinically adaptable, quantitatively verifiable, and diagnostically more reliable.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-12 in cs.AI).
Categorie arXiv: Artificial Intelligence (cs.AI) ; Computation and Language (cs.CL); Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2608.10505 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-19T05:57:28.278Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-08-12?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).