Metraipolis › archive › dc_dc9cec3aa7a8
Rethinking the Test-Time Prompt Tuning Objective from the Perspective of Calibration — arXiv:2608.30230
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.30230
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T07:44:34.223Z
- SHA-256 of the archived text
d4f6b358059e351c2dca137e135b9202319ef277a119d0e38997f6b946173d20- Stable URL of this page
https://metraipolis.com/documento/dc_dc9cec3aa7a8
How to cite
Rethinking the Test-Time Prompt Tuning Objective from the Perspective of Calibration — arXiv:2608.30230 — arXiv (en), https://arxiv.org/abs/2608.30230 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_dc9cec3aa7a8 (Metraipolis archive dc_dc9cec3aa7a8, sha256 d4f6b358059e351c2dca137e135b9202319ef277a119d0e38997f6b946173d20)
BibTeX
@misc{dcdc9cec3aa7a8,
title = {Rethinking the Test-Time Prompt Tuning Objective from the Perspective of Calibration — arXiv:2608.30230},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.30230},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_dc9cec3aa7a8; sha256 d4f6b358059e351c2dca137e135b9202319ef277a119d0e38997f6b946173d20},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.30230. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Test-time prompt tuning (TPT) has emerged as a powerful paradigm, refining prompts for each test sample via entropy minimization (EM) over multiple augmented views. However, we identify a limitation in the standard EM-based adaptation: it inherently drives the model toward overconfident predictions disregarding sample-specific uncertainty, leading to significant calibration degradation. To address these limitations, we propose a new objective that replaces the conventional EM loss by aligning the original-view prediction with a target distribution derived from augmented views via cross-entropy, while adversarially incorporating the entropy of the target distribution to capture sample-specific uncertainty. Furthermore, to better construct this target distribution, we apply confidence-aware temperature scaling to each augmented-view prediction according to its confidence, sharpening confident predictions while softening uncertain ones. This formulation allows the model to increase confidence only when the target distribution is reliable, while preserving uncertainty when it reflects ambiguous or conflicting augmented-view predictions. Extensive experiments across diverse benchmarks demonstrate that our approach not only achieves state-of-the-art accuracy but also significantly improves model calibration. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-01 in cs.AI). Categorie arXiv: Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2608.30230 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-17T07:28:26.590Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).