Metraipolis › archive › dc_dc5b419a52d4
Hybrid Ensemble Learning for EEG-Based Epileptic Seizure Forecasting — arXiv:2609.35876
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.35876
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-07T17:28:32.248Z
- SHA-256 of the archived text
e86b07fc32562bc9d752856f730cab7afd1de67241109cb29d8bfcde56da0dd0- Stable URL of this page
https://metraipolis.com/documento/dc_dc5b419a52d4
How to cite
Hybrid Ensemble Learning for EEG-Based Epileptic Seizure Forecasting — arXiv:2609.35876 — arXiv (en), https://arxiv.org/abs/2609.35876 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_dc5b419a52d4 (Metraipolis archive dc_dc5b419a52d4, sha256 e86b07fc32562bc9d752856f730cab7afd1de67241109cb29d8bfcde56da0dd0)
BibTeX
@misc{dcdc5b419a52d4,
title = {Hybrid Ensemble Learning for EEG-Based Epileptic Seizure Forecasting — arXiv:2609.35876},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.35876},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_dc5b419a52d4; sha256 e86b07fc32562bc9d752856f730cab7afd1de67241109cb29d8bfcde56da0dd0},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.35876. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Epileptic seizure forecasting aims to provide actionable warnings before seizure onset, yet patient-independent generalization and false-alarm control remain major challenges. We propose a calibrated hybrid ensemble for EEG-based seizure forecasting that combines five deep learning models and three classical machine learning models through a logistic regression stacking meta-learner. The proposed pipeline integrates signal preprocessing, handcrafted feature extraction, class-imbalance handling, probability calibration, and clinically motivated post-processing. We evaluate the framework on CHB-MIT using strict Leave-One-Patient-Out (LOPO) cross-validation, with threshold and post-processing parameters selected only on held-out meta data. On the filtered cohort, excluding patients with anomalous preictal rates below 1\% or above 15\%, the model achieves 74.2\% seizure-level sensitivity at 1.24 false alarms per hour, with an average warning time of 16.9 minutes. A test-tuned oracle constrained to the target false-alarm budget achieves 60.9\% sensitivity at 0.951 false alarms per hour, highlighting the importance of reporting sensitivity together with realized false-alarm rates. Our code is available at: this https URL Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-30 in cs.LG). Categorie arXiv: Machine Learning (cs.LG). Pagina del lavoro: https://arxiv.org/abs/2609.35876 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-07T16:59:48.071Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-09-30?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).