Metraipolis › archive › dc_dbfe52d91f29

MedPAO-VL: Interpretable and Protocol-Compliant Agent for Structured Radiology Report Generation — arXiv:2610.21794

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.21794
License (as archived)
CC0-1.0
Archived
2026-10-16T10:35:30.248Z
SHA-256 of the archived text
65ce10dc2c1de940e23f42fcab1cd59804460f8225bda86663f8d3605cf023fa
Stable URL of this page
https://metraipolis.com/documento/dc_dbfe52d91f29

How to cite

MedPAO-VL: Interpretable and Protocol-Compliant Agent for Structured Radiology Report Generation — arXiv:2610.21794 — arXiv (en), https://arxiv.org/abs/2610.21794 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_dbfe52d91f29 (Metraipolis archive dc_dbfe52d91f29, sha256 65ce10dc2c1de940e23f42fcab1cd59804460f8225bda86663f8d3605cf023fa)
BibTeX
@misc{dcdbfe52d91f29,
  title = {MedPAO-VL: Interpretable and Protocol-Compliant Agent for Structured Radiology Report Generation — arXiv:2610.21794},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.21794},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_dbfe52d91f29; sha256 65ce10dc2c1de940e23f42fcab1cd59804460f8225bda86663f8d3605cf023fa},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.21794. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Despite the remarkable generalization capabilities of Large Language Models, generating clinically accurate and structured radiology reports from medical images remains a significant challenge. Current end-to-end approaches function as black boxes, prone to factual hallucinations and generating ungrounded findings. This lack of reliability and failure to adhere to domain-specific structuring protocols, fundamentally limits their clinical utility. We present MedPAO-VL, a multimodal agent that shifts the paradigm from monolithic generation to explainable, iterative, protocol-compliant structured report generation. Unlike deterministic models, our plan-act-observe loop functions as a goal-oriented agent: it first perceives the Chest X-Ray through an explainable vision module designed to capture inherent diagnostic uncertainty, then iteratively refines the generated report by observing semantic discrepancies and self-correcting its generation for better alignment with visually detected clinical findings. Evaluation of our framework demonstrates that this agentic reasoning improves clinical correctness and completeness, achieving an expert-rated accuracy score of 3.5/5 and a structural score of 4.3/5. By prioritizing pathology specific explainability and iterative refinement over opaque end-to-end mapping, MedPAO-VL offers a transparent and clinically viable alternative for automated structured radiology report generation.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2610.21794 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T08:52:02.700Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).